FDA label ba0c7c30-0246-4de1-82f6-3208baadda05

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

SPL set ID
b53a7c5d-2de6-40a3-9015-ca18cf84df19
SPL ID
ba0c7c30-0246-4de1-82f6-3208baadda05
Version
2
Effective date
2013-10-03
Source export date
2026-10-12
Source partition
13
Source file
https://download.open.fda.gov/drug/label/drug-label-0013-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-10-12/b8dac220ac9fc8ffb4d86c6e00ece30169fc4575ca0cc92e5c9ce1a524fb0249/drug-label-0013-of-0014.json.zip
Source manifest SHA-256
7e6b178df8f32cac9a78e0f5d09c588344509b04fe41effb1dde9102e2a45be6
Import run
20261013T011858Z
Imported at
2026-10-13 03:04:26

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings

WARNINGS Glucagon should be administered cautiously to patients with a history suggestive of insulinoma, pheochromocytoma, or both. In patients with insulinoma, intravenous administration of glucagon may produce an initial increase in blood glucose; however, because of glucagon's hyperglycemic effect the insulinoma may release insulin and cause subsequent hypoglycemia. A patient developing symptoms of hypoglycemia after a dose of glucagon should be given glucose orally, intravenously, or by gavage, whichever is most appropriate. Exogenous glucagon also stimulates the release of catecholamines. In the presence of pheochromocytoma, glucagon can cause the tumor to release catecholamines, which may result in a sudden and marked increase in blood pressure. If a patient develops a sudden increase in blood pressure, 5 to 10 mg of phentolamine mesylate may be administered intravenously in an attempt to control the blood pressure. Generalized allergic reactions, including urticaria, respiratory distress, and hypotension, have been reported in patients who received glucagon by injection.

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 1 matching rows.

adverse reactions

ADVERSE REACTIONS Severe adverse reactions are very rare, although nausea and vomiting may occur occasionally. These reactions may also occur with hypoglycemia. Generalized allergic reactions have been reported ( ). In a three month controlled study of 75 volunteers comparing animal-sourced glucagon with glucagon manufactured through rDNA technology, no glucagon-specific antibodies were detected in either treatment group. see WARNINGS

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.