VUITY

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

Brand name
VUITY
Generic name
PILOCARPINE HYDROCHLORIDE
Manufacturer
AbbVie Inc.
Product type
HUMAN PRESCRIPTION DRUG
SPL set ID
8d806897-8a2a-4518-8c68-0ec3b778de50
SPL ID
ed4cf150-c4b6-4d26-9326-e3a3490de489
Version
14
Effective date
2023-03-28
Source export date
2026-09-28
Source partition
12
Source file
https://download.open.fda.gov/drug/label/drug-label-0012-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-09-28/663999d0fe1757c1e2cd13a4799d76d875f663e0bc57701092264ebe7febfc18/drug-label-0012-of-0014.json.zip
Source manifest SHA-256
cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
Import run
20260929T050834Z
Imported at
2026-09-29 06:27:31
Harmonized routes table
Harmonized routes
OPHTHALMIC

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings and cautions

5 WARNINGS AND PRECAUTIONS Blurred Vision : Patients should be advised not to drive or operate machinery if vision is not clear (e.g., blurred vision). Exercise caution in night driving and other hazardous activities in poor illumination. ( 5.1 ) Risk of Retinal D etachment : Rare cases of retinal detachment and retinal tear have been reported with miotics, including VUITY. Individuals with pre-existing retinal disease are at increased risk. Therefore, examination of the retina is advised in all patients prior to initiation of therapy. Patients should be advised to seek immediate medical care with sudden onset of flashing lights, floaters, or vision loss. ( 5.2 ) Iritis : Caution is advised in patients with iritis. ( 5.3 ) 5.1 Blurred Vision Miotics, including VUITY, may cause accommodative spasm. Patients should be advised not to drive or operate machinery if vision is not clear (e.g., blurred vision). In addition, patients may experience temporary dim or dark vision with miotics, including VUITY. Patients should be advised to exercise caution in night driving and other hazardous activities in poor illumination. 5. 2 Risk of Retinal D etachment Rare cases of retinal detachment and retinal tear have been reported with miotics, including VUITY. Individuals with pre-existing retinal disease are at increased risk. Therefore, examination of the retina is advised in all patients prior to the initiation of therapy. Patients should be advised to seek immediate medical care with sudden onset of flashing lights, floaters, or vision loss. 5. 3 Iritis VUITY is not recommended to be used when iritis is present because adhesions (synechiae) may form between the iris and the lens. 5. 4 Use with Contact Lenses Contact lens wearers should be advised to remove their lenses prior to the instillation of VUITY and to wait 10 minutes after dosing before reinserting their contact lenses. 5. 5 Potential for Eye Injury or Contamination To prevent eye injury or contamination, care should be taken to avoid touching the dispensing bottle to the eye or to any other surface.

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 1 matching rows.

adverse reactions

6 ADVERSE REACTIONS The following clinically significant adverse reactions are described elsewhere in labeling: Hypersensitivity [see Contraindications ( 4 )] Most common adverse reactions (>5%) are headache, conjunctival hyperemia, and eye irritation. ( 6.1 ) To report SUSPECTED ADVERSE REACTIONS, contact Allergan at 1-800-678-1605 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch. 6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. VUITY dosed once daily was evaluated in 375 participants with presbyopia in two randomized, double-masked, vehicle-controlled studies (GEMINI 1 and GEMINI 2) of 30 days duration. The most common adverse reactions reported in >5% of participants were headache and conjunctival hyperemia. Ocular adverse reactions reported in 1-5% of participants were blurred vision, eye pain, visual impairment, eye irritation, and increased lacrimation. VUITY was also evaluated in 114 participants with presbyopia in a randomized, double-masked, vehicle-controlled 14-day study (VIRGO) in which participants received two doses of VUITY in each eye, 6 hours apart daily. The most common adverse reactions reported in >5 % of participants were headache and eye irritation. Ocular adverse reactions reported in 1-5% of participants were visual impairment, eye pain, blurred vision, and vitreous floaters. 6.2 Postmarketing Experience The following adverse reactions have been identified during postapproval use of VUITY. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to VUITY exposure. Eye disorders : vitreous detachment, vitreomacular traction, retinal tear, retinal detachment.

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.