AMONDYS 45
openFDA label record#
This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.
Verified complete openFDA source JSON
- Brand name
- AMONDYS 45
- Generic name
- CASIMERSEN
- Manufacturer
- Sarepta Therapeutics, Inc.
- Product type
- HUMAN PRESCRIPTION DRUG
- SPL set ID
- e9e5fd44-eeda-4580-bba1-a734828bbcc3
- SPL ID
- f388df1b-13aa-4b95-a7fa-9694dc86981c
- Version
- 11
- Effective date
- 2026-01-09
- Source export date
- 2026-10-12
- Source partition
- 1
- Source file
- https://download.open.fda.gov/drug/label/drug-label-0001-of-0014.json.zip
- Source object key
- raw/openfda/drug-label/2026-10-12/7928c8e8c6256620071a8b7e5b93eb8dfa543649c08d17a01ea02251012ba58c/drug-label-0001-of-0014.json.zip
- Source manifest SHA-256
- 7e6b178df8f32cac9a78e0f5d09c588344509b04fe41effb1dde9102e2a45be6
- Import run
- 20261013T011858Z
- Imported at
- 2026-10-13 01:25:09
| Harmonized routes |
|---|
| INTRAVENOUS |
Harmonized identifier links#
Every typed identifier imported from the complete openFDA harmonization object is paginated here; values are not reduced to a first match.
| Type | Scope | Identifier | Source field |
|---|---|---|---|
| application applno | NDA | 213026 | derived:openfda.application_number |
| application number | NDA213026 | openfda.application_number | |
| brand name | AMONDYS 45 | openfda.brand_name | |
| generic name | CASIMERSEN | openfda.generic_name | |
| manufacturer name | Sarepta Therapeutics, Inc. | openfda.manufacturer_name | |
| ndc | package | 60923-227-02 | openfda.package_ndc |
| ndc | product | 60923-227 | openfda.product_ndc |
| ndc11 | package | 60923022702 | derived:openfda.package_ndc |
| rxcui | 2480100 | openfda.rxcui | |
| rxcui | 2480105 | openfda.rxcui | |
| spl id | f388df1b-13aa-4b95-a7fa-9694dc86981c | id | |
| spl set id | e9e5fd44-eeda-4580-bba1-a734828bbcc3 | set_id | |
| unii | X8UHF7SX0R | openfda.unii |
Warnings cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
5 WARNINGS AND PRECAUTIONS Hypersensitivity Reactions: Hypersensitivity reactions, including angioedema and anaphylaxis, have occurred in patients who were treated with AMONDYS 45. If a hypersensitivity reaction occurs, institute appropriate medical treatment and consider slowing the infusion, interrupting or discontinuing the AMONDYS 45 infusion ( 2.4 , 5.1 ) Kidney Toxicity: Based on animal data, may cause kidney toxicity. Kidney function should be monitored; creatinine may not be a reliable measure of renal function in DMD patients. ( 5.2 , 13.2 ) 5.1 Hypersensitivity Reactions Hypersensitivity reactions, including angioedema and anaphylaxis, have occurred in patients who were treated with AMONDYS 45. If a hypersensitivity reaction occurs, institute appropriate medical treatment, and consider slowing the infusion [see Dosage and Administration ( 2.4 )] , interrupting, or discontinuing the AMONDYS 45 infusion and monitor until the condition resolves. AMONDYS 45 is contraindicated in patients with known serious hypersensitivity to casimersen or to any of the inactive ingredients in AMONDYS 45 [see Contraindications ( 4 )] . 5.2 Kidney Toxicity Kidney toxicity was observed in animals who received casimersen [see Use in Specific Populations ( 8.4 ) and Nonclinical Toxicology ( 13.2 )] . Although kidney toxicity was not observed in the clinical studies with AMONDYS 45, kidney toxicity, including potentially fatal glomerulonephritis, has been observed after administration of some antisense oligonucleotides. Kidney function should be monitored in patients taking AMONDYS 45. Because of the effect of reduced skeletal muscle mass on creatinine measurements, creatinine may not be a reliable measure of kidney function in DMD patients. Serum cystatin C, urine dipstick, and urine protein-to-creatinine ratio should be measured before starting AMONDYS 45. Consider also measuring glomerular filtration rate using an exogenous filtration marker before starting AMONDYS 45. During treatment, monitor urine dipstick every month, and serum cystatin C and urine protein-to-creatinine ratio (UPCR) every three months. Only urine expected to be free of excreted AMONDYS 45 should be used for monitoring of urine protein. Urine obtained on the day of AMONDYS 45 infusion prior to the infusion, or urine obtained at least 48 hours after the most recent infusion, may be used. Alternatively, use a laboratory test that does not use the reagent pyrogallol red, as this reagent has the potential to cross react with any AMONDYS 45 that is excreted in the urine and thus lead to a false positive result for urine protein. If a persistent increase in serum cystatin C or proteinuria is detected, refer to a pediatric nephrologist for further evaluation.
Adverse reactions cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
adverse reactions
6 ADVERSE REACTIONS The following clinically significant adverse reactions are described elsewhere in the labeling: Hypersensitivity reactions [see Warnings and Precautions ( 5.1 )] The most common adverse reactions (incidence >20% and at least 5% higher than placebo) were upper respiratory tract infection, cough, pyrexia, headache, arthralgia, and oropharyngeal pain. ( 6.1 ) To report SUSPECTED ADVERSE REACTIONS, contact Sarepta Therapeutics, Inc. at 1-888-SAREPTA (1-888-727-3782) or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch . 6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. In the AMONDYS 45 clinical development program, 76 patients received at least one intravenous dose of AMONDYS 45 (30 mg/kg). All patients were male and had genetically confirmed Duchenne muscular dystrophy. Age at study entry was 7 to 20 years (mean 9.9 years). Most (88%) patients were White, and 9% were Asian. AMONDYS 45 was studied in a double-blind, placebo-controlled study (Study 1). Patients in ongoing Study 1 received AMONDYS 45 (n=57) 30 mg/kg or placebo (n=31) intravenously once weekly for up to 96 weeks, after which all patients received or will receive AMONDYS 45 30 mg/kg for up to 48 weeks. Adverse reactions observed in ≥20% of patients treated with AMONDYS 45 and 5% more frequently than in the placebo group in Study 1 are shown in Table 1 . Table 1. Adverse Reactions Occurring in at Least 20% of Patients Treated with AMONDYS 45 and at a Rate at Least 5% More Frequently than in the Placebo Group in Study 1 *Includes upper respiratory infection, pharyngitis, nasopharyngitis, and rhinitis. Adverse Reaction AMONDYS 45 30 mg/kg Once Weekly (n = 57) % Placebo (n = 31) % Upper Respiratory Tract Infections* 65 55 Cough 33 26 Pyrexia 33 23 Headache 32 19 Arthralgia 21 10 Oropharyngeal Pain 21 7 Other adverse reactions that occurred in at least 10% of patients treated with AMONDYS 45, and that were reported at a rate at least 5% more frequently in the AMONDYS 45 group than in the placebo group, were: ear pain, nausea, ear infection, post-traumatic pain, and dizziness and light-headedness. 6.2 Postmarketing Experience The following adverse reactions have been identified during postapproval use of AMONDYS 45. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. Infusion-related reactions including rash, headache, cough, abdominal pain (including upper abdominal pain), and vomiting occurred within 24 hours from the start of an infusion of AMONDYS 45. Hypersensitivity reactions, including angioedema and anaphylaxis, have occurred in patients treated with AMONDYS 45.
adverse reactions table
<table ID="t1" width="100%"><caption>Table 1. Adverse Reactions Occurring in at Least 20% of Patients Treated with AMONDYS 45 and at a Rate at Least 5% More Frequently than in the Placebo Group in Study 1 </caption><col width="39.413%" align="left"/><col width="29.843%" align="left"/><col width="30.744%" align="left"/><tfoot><tr><td colspan="3" align="left" valign="top"><paragraph styleCode="footnote">*Includes upper respiratory infection, pharyngitis, nasopharyngitis, and rhinitis. </paragraph></td></tr></tfoot><tbody><tr><td align="left" valign="top" styleCode="Toprule Botrule Lrule Rrule">Adverse Reaction </td><td align="center" valign="top" styleCode="Toprule Botrule Rrule">AMONDYS 45 30 mg/kg Once Weekly (n = 57) % </td><td align="center" valign="top" styleCode="Toprule Botrule Rrule">Placebo (n = 31) % </td></tr><tr><td align="left" valign="top" styleCode="Botrule Lrule Rrule">Upper Respiratory Tract Infections* </td><td align="center" valign="top" styleCode="Botrule Rrule">65 </td><td align="center" valign="top" styleCode="Botrule Rrule">55 </td></tr><tr><td align="left" valign="top" styleCode="Botrule Lrule Rrule">Cough </td><td align="center" valign="top" styleCode="Botrule Rrule">33 </td><td align="center" valign="top" styleCode="Botrule Rrule">26 </td></tr><tr><td align="left" valign="top" styleCode="Botrule Lrule Rrule">Pyrexia </td><td align="center" valign="top" styleCode="Botrule Rrule">33 </td><td align="center" valign="top" styleCode="Botrule Rrule">23 </td></tr><tr><td align="left" valign="top" styleCode="Botrule Lrule Rrule">Headache </td><td align="center" valign="top" styleCode="Botrule Rrule">32 </td><td align="center" valign="top" styleCode="Botrule Rrule">19 </td></tr><tr><td align="left" valign="top" styleCode="Botrule Lrule Rrule">Arthralgia </td><td align="center" valign="top" styleCode="Botrule Rrule">21 </td><td align="center" valign="top" styleCode="Botrule Rrule">10 </td></tr><tr><td align="left" valign="top" styleCode="Botrule Lrule Rrule">Oropharyngeal Pain </td><td align="center" valign="top" styleCode="Botrule Rrule">21 </td><td align="center" valign="top" styleCode="Botrule Rrule">7 </td></tr></tbody></table>
Reported adverse events (FAERS/openFDA)#
Adverse event summaries are temporarily unavailable. Other product information remains available.