Fluorodopa F18

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

Brand name
Fluorodopa F18
Generic name
FLUORODOPA F18
Manufacturer
THE FEINSTEIN INSTITUTES FOR MEDICAL RESEARCH
Product type
HUMAN PRESCRIPTION DRUG
SPL set ID
37f8c405-ccb6-4fcd-8513-108956bb1674
SPL ID
f8d69c66-d9aa-4bb8-bb56-5bebeef87af5
Version
20210115
Effective date
2021-01-15
Source export date
2026-09-28
Source partition
4
Source file
https://download.open.fda.gov/drug/label/drug-label-0004-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-09-28/c7ca0b7091cdaeab3f27713a6eef00adcf8fe722383633ddce61531b4c840544/drug-label-0004-of-0014.json.zip
Source manifest SHA-256
cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
Import run
20260929T050834Z
Imported at
2026-09-29 05:23:04
Harmonized routes table
Harmonized routes
INTRAVENOUS

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 2 matching rows.

warnings and cautions

5 WARNINGS AND PRECAUTIONS Radiation risks: Use smallest dose necessary for imaging and ensure safe handling to protect the patient and healthcare worker from radiation exposure. ( 5.1 ) 5.1 Radiation Risks Fluorodopa F 18 Injection use contributes to a patient’s overall long-term radiation exposure, which is associated with an increased risk of cancer. Use the smallest dose necessary for imaging and ensure safe handling to protect the patient and health care worker [see Dosage and Administration ( 2.1 , 2.2 )] .

warnings and cautions

5.1 Radiation Risks Fluorodopa F 18 Injection use contributes to a patient’s overall long-term radiation exposure, which is associated with an increased risk of cancer. Use the smallest dose necessary for imaging and ensure safe handling to protect the patient and health care worker [see Dosage and Administration ( 2.1 , 2.2 )] .

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 3 matching rows.

adverse reactions

6 ADVERSE REACTIONS Injection site pain occurred with administration based on a review of the published literature. ( 6.2 ) To report SUSPECTED ADVERSE REACTIONS, contact The Feinstein Institutes for Medical Research at 516-562-1052 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch . 6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. No adverse reactions have been reported for Fluorodopa F 18 Injection based on an open-label clinical trial in 68 patients [see Clinical Studies ( 14 ) ] and additional clinical experience in 53 patients. 6.2 Postmarketing Experience The following adverse reactions have been identified during post approval of use of Fluorodopa F 18 Injection outside of the United States. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. General Disorders and Administration Site Conditions: Pain

adverse reactions

6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. No adverse reactions have been reported for Fluorodopa F 18 Injection based on an open-label clinical trial in 68 patients [see Clinical Studies ( 14 ) ] and additional clinical experience in 53 patients.

adverse reactions

6.2 Postmarketing Experience The following adverse reactions have been identified during post approval of use of Fluorodopa F 18 Injection outside of the United States. Because these reactions are reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. General Disorders and Administration Site Conditions: Pain

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.