CERIANNA

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

Brand name
CERIANNA
Generic name
FLUOROESTRADIOL F 18
Manufacturer
GE Healthcare Inc.
Product type
HUMAN PRESCRIPTION DRUG
SPL set ID
b2c2a2df-cf3e-4a29-a033-231ed5a94b58
SPL ID
fd28ffaf-5b17-43e7-bc91-fd623819340e
Version
27
Effective date
2026-01-12
Source export date
2026-09-28
Source partition
4
Source file
https://download.open.fda.gov/drug/label/drug-label-0004-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-09-28/c7ca0b7091cdaeab3f27713a6eef00adcf8fe722383633ddce61531b4c840544/drug-label-0004-of-0014.json.zip
Source manifest SHA-256
cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
Import run
20260929T050834Z
Imported at
2026-09-29 05:27:20
Harmonized routes table
Harmonized routes
INTRAVENOUS

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings and cautions

5 WARNINGS AND PRECAUTIONS Risk of Misdiagnosis . Do not use CERIANNA in lieu of biopsy when biopsy is indicated in patients with recurrent or metastatic breast cancer. Pathology or clinical characteristics that suggest a patient may benefit from systemic hormone therapy should take precedence over a discordant negative CERIANNA scan. ( 5.1 ) Radiation Risks . Ensure safe drug handling and patient preparation procedures to protect patients and health care providers from unintentional radiation exposure. ( 2.1 , 2.3 , 5.2 ) 5.1 Risk of Misdiagnosis Inadequate Tumor Characterization and Other ER-Positive Pathology Breast cancer may be heterogeneous within patients and across time. CERIANNA images ER and is not useful for imaging other receptors such as HER2 and PR. The uptake of fluoroestradiol F 18 is not specific for breast cancer and may occur in a variety of ER-positive tumors that arise outside of the breast, including from the uterus and ovaries. Do not use CERIANNA in lieu of biopsy when biopsy is indicated in patients with recurrent or metastatic breast cancer. False Negative CERIANNA Scan A negative CERIANNA scan does not rule out ER-positive breast cancer [see Clinical Studies (14) ] . Pathology or clinical characteristics that suggest a patient may benefit from systemic hormone therapy should take precedence over a discordant negative CERIANNA scan. 5.2 Radiation Risks Diagnostic radiopharmaceuticals, including CERIANNA, expose patients to radiation [see Dosage and Administration (2.6) ] . Radiation exposure is associated with a dose-dependent increased risk of cancer. Ensure safe drug handling and patient preparation procedures to protect patients and health care providers from unintentional radiation exposure [see Dosage and Administration (2.1) and (2.3) ] .

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 1 matching rows.

adverse reactions

6 ADVERSE REACTIONS Reported adverse reactions include: injection-site pain and dysgeusia ( 6 ) To report SUSPECTED ADVERSE REACTIONS, contact GE HealthCare at 1-800-654-0118 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch . 6.1 Clinical Trials Experience Because clinical trials are conducted under widely varying conditions, adverse reaction rates observed in the clinical trials of a drug cannot be directly compared to rates in the clinical trials of another drug and may not reflect the rates observed in practice. The safety of CERIANNA was evaluated from published clinical studies of 1,207 patients with breast cancer receiving at least one fluoroestradiol F 18 administration. The following adverse reactions occurred at a rate < 1%: General disorders : injection-site pain Neurological and gastrointestinal disorders : dysgeusia

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.