- Primary DI
- 00812480010956
- Brand
- NA
- Company
- MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC.
- Model
- 2355CE
- Catalog number
- 2355CE
- Device description
- 20 Gauge Vitreous Cutter, AP, w/ 72” Anterior Tubing Set, Sterile, Extended Use
- Published
- 2016-09-23
- Public version status
- Update
- Distribution status
- Not in Commercial Distribution
- MRI safety
- Labeling does not contain MRI Safety Information
- Rx
- true
- Sterile
- true
Contact Domains#
Product Codes#
Product Code Classifications#
Identifiers And Packaging#
| Identifier | Type | Agency | Package quantity | Status |
|---|---|---|---|---|
| 10812480010953 | Package | GS1 | 6 | Not in Commercial Distribution |
| 00812480010956 | Primary | GS1 | 0 |
Alternate GTIN / UPC / EAN Codes
| Source identifier | GTIN-14 normalized | UPC-A | EAN-13 |
|---|---|---|---|
| 10812480010953 | 10812480010953 | ||
| 00812480010956 | 00812480010956 | 812480010956 | 0812480010956 |
GMDN Terms#
| Term | Definition |
|---|---|
| Vitrectomy system handpiece | A holder for a detachable, micro-cutting tip that converts the energy (e.g., ultrasonic, piezoelectric) produced by a system generator into a mechanical oscillating-cutting action to remove (nibble away) vitreous humour (the jelly-like substance that fills the centre of the eye) during ophthalmic surgery. This device will typically be activated by the surgeon using a foot control and provide or support the irrigation/suction systems needed to supply replacement fluid and remove debris. The handpiece is typically designed in the form of a pen or pencil, and connected to the generator via a cable. This is a reusable device intended to be sterilized prior to use. |
Device Sizes#
| Type | Value | Unit |
|---|---|---|
| Needle Gauge | 20 | Gauge |
Storage And Handling#
| Type | Low | High | Condition |
|---|---|---|---|
| Handling Environment Humidity | 10 Percent (%) Relative Humidity | 90 Percent (%) Relative Humidity | |
| Handling Environment Temperature | -40 Degrees Celsius | 60 Degrees Celsius | |
| Storage Environment Humidity | 10 Percent (%) Relative Humidity | 90 Percent (%) Relative Humidity | |
| Storage Environment Temperature | -40 Degrees Celsius | 60 Degrees Celsius |
Sterilization Methods#
| Method |
|---|
| Moist Heat or Steam Sterilization |
Contacts#
| Phone | |
|---|---|
| 1(800)929-5227 | qa@midlabs.com |
Regulatory Flags#
- DUNS number
- 790265227
- Device count
- 1
- Lot or batch
- true
- Expiration date on label
- true
- Sterilization required before use
- true
Other Devices From This Company#
| Primary DI | Brand | Model | Catalog | Published |
|---|---|---|---|---|
| 00812480011083 | Bi-Blade® | 2620BB | 2620BB | 2026-09-26 |
| 00812480011090 | Bi-Blade® | 2640BB | 2640BB | 2026-09-26 |
| 00812480011137 | Bi-Blade® | 2810BB | 2810BB | 2026-09-27 |
| 00812480011144 | Bi-Blade® | 2870BB | 2870BB | 2026-09-26 |
| 00812480011151 | Bi-Blade® | 2890BB | 2890BB | 2026-09-27 |
| 00812480011168 | Bi-Blade® | 2910BB | 2910BB | 2026-09-27 |
| 00812480011175 | Bi-Blade® | 2970BB | 2970BB | 2026-09-27 |
| 00812480011182 | Bi-Blade® | 2990BB | 2990BB | 2026-09-27 |
| 00812480013049 | NA | 2700CN | 2700CN | 2026-09-27 |
| 00812480011038 | Bi-Blade® | 2410BB | 2410BB | 2023-08-14 |
| 00812480011007 | Bi-Blade® | 2310BB | 2310BB | 2023-08-14 |
| 10812480011035 | Bi-Blade® | 2410BB | 2410BB | 2023-08-14 |
| 00812480011045 | Bi-Blade® | 2510BB | 2510BB | 2018-11-16 |
| 00812480010741 | Bi-Blade® | 2320BB | 2320BB | 2018-09-24 |
| 00812480010826 | Bi-Blade® | 2520BB | 2520BB | 2018-09-24 |
| 00812480010833 | Bi-Blade® | 2540BB | 2540BB | 2018-09-24 |
| 00812480010840 | Bi-Blade® | 2560BB | 2560BB | 2018-09-24 |
| 00812480010918 | Bi-Blade™ | 2920BB | 2920BB | 2018-09-24 |
| 00812480010925 | Bi-Blade™ | 2940BB | 2940BB | 2018-09-24 |
| 00812480010932 | Bi-Blade™ | 2960BB | 2960BB | 2018-09-24 |
Other Devices Sharing Product Codes#
| Primary DI | Brand | Company | Product code | Published |
|---|---|---|---|---|
| 00812480011137 | Bi-Blade® | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-27 |
| 00812480011151 | Bi-Blade® | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-27 |
| 00812480011168 | Bi-Blade® | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-27 |
| 00812480011175 | Bi-Blade® | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-27 |
| 00812480011182 | Bi-Blade® | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-27 |
| 00812480013049 | NA | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-27 |
| 00812480011083 | Bi-Blade® | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-26 |
| 00812480011090 | Bi-Blade® | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-26 |
| 00812480011144 | Bi-Blade® | MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC. | HQE | 2026-09-26 |
| 10757770060464 | Bausch + Lomb | Bausch & Lomb Incorporated | HQE | 2026-04-09 |
| 10757770060471 | Bausch + Lomb | Bausch & Lomb Incorporated | HQE | 2026-04-09 |
| 10757770060488 | Bausch + Lomb | Bausch & Lomb Incorporated | HQE | 2026-04-09 |
| 08717872036540 | 27G Two Dimensional Cutter – 20k CPM | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2025-04-01 |
| 08717872036526 | EVA Cartridge with 0.5 L Collection Bag | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2025-03-31 |
| 08717872036588 | Disposable EVA Air Fluid Dual Tubing | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2025-03-31 |
| 08717872036489 | EVA NEXUS™ Irrigation and Aux. Aspiration Tubing | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2025-03-31 |
| 08717872036496 | EVA NEXUS™ Infusion Giving Set | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2025-03-31 |
| 08717872036502 | EVA Nexus™ Irrigation Tubing | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2025-03-31 |
| 08717872036618 | EVA Nexus™ Aux. Aspiration Tubing | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2025-03-31 |
| 08717872036625 | EVA NEXUS™ cartridge with 0,5 L collection bag | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2025-03-31 |
| 08717872034713 | CUSTOM TDC VITREC.PACK VGP 25G | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-09-27 |
| 08717872035109 | EVA NEXUS™ Posterior 23G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |
| 08717872035116 | EVA NEXUS™ Posterior 25G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |
| 08717872035123 | EVA NEXUS™ Posterior 27G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |
| 08717872035307 | EVA NEXUS™ Posterior 23G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |
| 08717872035314 | EVA NEXUS™ Posterior 25G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |
| 08717872035321 | EVA NEXUS™ Posterior 27G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |
| 08717872035338 | EVA NEXUS™ Combined 23G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |
| 08717872035345 | EVA NEXUS™ Combined 25G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |
| 08717872035352 | EVA NEXUS™ Combined 27G TDC Pack | D.O.R.C. Dutch Ophthalmic Research Center (International) B.V. | HQE | 2024-02-21 |