2405CE

GUDID 00812480010963

20 Gauge Vitreous Cutter, SP, w/ 79” Posterior Tubing Set, Sterile, Extended Use

MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC.

Vitrectomy system handpiece
Primary Device ID00812480010963
NIH Device Record Key72d4b166-5fab-4717-892e-d644a3afc401
Commercial Distribution Discontinuation2018-01-04
Commercial Distribution StatusNot in Commercial Distribution
Version Model Number2405CE
Catalog Number2405CE
Company DUNS790265227
Company NameMEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC.
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kitfalse
Device Combination Productfalse
Single Usefalse
Lot Batchtrue
Serial Numberfalse
Manufacturing Datefalse
Expiration Datetrue
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptiontrue
OTC Over-The-Counterfalse

Customer Support Contacts

Phone1(800)929-5227
Emailqa@midlabs.com
Phone1(800)929-5227
Emailqa@midlabs.com

Device Dimensions

Needle Gauge20 Gauge
Needle Gauge20 Gauge

Operating and Storage Conditions

Handling Environment HumidityBetween 10 Percent (%) Relative Humidity and 90 Percent (%) Relative Humidity
Handling Environment HumidityBetween 10 Percent (%) Relative Humidity and 90 Percent (%) Relative Humidity
Handling Environment HumidityBetween 10 Percent (%) Relative Humidity and 90 Percent (%) Relative Humidity
Handling Environment HumidityBetween 10 Percent (%) Relative Humidity and 90 Percent (%) Relative Humidity
Handling Environment HumidityBetween 10 Percent (%) Relative Humidity and 90 Percent (%) Relative Humidity
Handling Environment HumidityBetween 10 Percent (%) Relative Humidity and 90 Percent (%) Relative Humidity
Handling Environment HumidityBetween 10 Percent (%) Relative Humidity and 90 Percent (%) Relative Humidity
Handling Environment HumidityBetween 10 Percent (%) Relative Humidity and 90 Percent (%) Relative Humidity

Device Identifiers

Device Issuing AgencyDevice ID
GS100812480010963 [Primary]
GS110812480010960 [Package]
Package: Carton [6 Units]
Discontinued: 2018-01-04
Not in Commercial Distribution

FDA Product Code

HKPInstrument, Vitreous Aspiration And Cutting, Battery-Powered

Sterilization

Steralize Prior To Usetrue
Device Is Steriletrue

[00812480010963]

Moist Heat or Steam Sterilization


[00812480010963]

Moist Heat or Steam Sterilization


Device Entry Metadata

Public Version StatusUpdate
Device Record StatusPublished
Public Version Number2
Public Version Date2018-03-29
Device Publish Date2016-09-23

Devices Manufactured by MEDICAL INSTRUMENT DEVELOPMENT LABORATORIES, INC.

00812480011007 - Bi-Blade®2023-08-22 27 Gauge BB Vitreous Cutter, 20 psi, Luer Anterior PVC Tubing Set, Sterile, Single Use
10812480011035 - Bi-Blade®2023-08-22 27 Gauge BB Vitreous Cutter, 25 psi, Luer Anterior PVC Tubing Set, Sterile, Single Use
10812480011219 - NA2021-05-05 Cannula Insertion System, 27 Gauge, Sterile, Single Step, Generic, w/ Tubing Set
10812480011233 - NA2021-05-05 Cannula Insertion System, 25 Gauge, Sterile, Single Step, Generic, w/ Tubing Set
10812480011257 - NA2021-05-05 Cannula Insertion System, 23 Gauge, Sterile, Single Step, Generic, w/ Tubing Set
10812480011028 - Bi-Blade®2018-12-17 25 Gauge BB Vitreous Cutter, R1+, w/ 79” Anterior Tubing Set, Sterile, Single Use, 1ea
10812480011042 - Bi-Blade®2018-12-17 27 Gauge BB Vitreous Cutter, R4+, w/ 72” Anterior Tubing Set, Sterile, Single Use
10812480011196 - Bi-Blade®2018-12-17 27 Gauge BB Vitreous Cutter, R3A, w/ 72” Anterior Tubing Set, Sterile, Single Use

© 2024 FDA.report
This site is not affiliated with or endorsed by the FDA.