Tracking Bracket

Primary DI
00841436120487
Brand
Tracking Bracket
Company
CIVCO MEDICAL INSTRUMENTS CO., INC.
Model
657-087
Catalog number
657-087
Device description
Reusable non-sterile tracking bracket for use with Samsung Medison LM2-18 transducers
Published
2022-04-29
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
IYOSystem, imaging, pulsed echo, ultrasonic

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
IYOSystem, Imaging, Pulsed Echo, UltrasonicRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K092619000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K092619000ETRAX NEEDLE SYSTEM, ETRAX VARIABLE ANGLE NEEDLE GUIDANCE SYSTEM, VIRTUTRAX UNIVERSAL TRACKERCivco2009-11-13IYO

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
20841436120467Direct MarkingGS10
00841436120487PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
2084143612046720841436120467
00841436120487008414361204878414361204870841436120487

GMDN Terms#

Term, Definition table
TermDefinition
Ultrasound imaging system tracking positioner, reusableA metal or plastic bracket intended to be applied to a hand-held ultrasound (US) transducer for the repeatable positioning (detach from/reattach to same place) of an electromagnetic (EM) sensor and/or needle guide on the transducer. It may be used in conjunction with an EM device tracking system and is intended for applications involving needle guidance and tracking such as ablation, core tissue biopsy, fluid aspiration, therapeutic delivery and vascular access. Disposable needle guides and imaging-supportive devices (e.g., US transducer cover/gel) may be included with the positioner; the transducer and sensor are not included. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Special Storage Condition, Specify00Keep Away from Sunlight

Contacts#

Phone, Email table
PhoneEmail
+1(319)248-6502regulatory@civco.com

Regulatory Flags#

DUNS number
134614411
Device count
1
Kit
true
Lot or batch
true
Manufacturing date on label
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00841436125482Needle Guide11820737118207372026-04-17
00841436108300TEE Kit811-050811-0502017-08-22
00841436108317TEE Kit811-051811-0512017-08-22
00841436108324TEE Kit811-052811-0522017-08-22
00841436108331TEE Kit811-053811-0532017-08-22
00841436108348TEE Kit811-054811-0542017-08-22
00841436108355TEE Kit811-055811-0552017-08-22
00841436108362TEE Kit811-056811-0562017-08-22
00841436108379TEE Kit811-057811-0572017-08-22
00841436111133Laparostat810-212810-2122017-08-22
10841436122655Needle Guide667-187667-1872025-12-31
10841436122662Needle Guide667-188667-1882025-12-31
10841436126240Needle Guide610-1557610-15572025-12-31
10841436126257Needle Guide610-1558610-15582025-12-31
00841436122894Verza Guidance System639-064639-0642025-12-31
00841436125345Verza Guidance System667-196667-1962025-12-31
00841436125802Verza Guidance SystemH48062APH48062AP2025-12-31
00841436125826Needle Guidance SystemH48062ARH48062AR2025-12-31
00841436125840Needle Guidance SystemH48062ASH48062AS2025-12-31
00841436126274Verza Guidance System657-115657-1152025-12-31

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00850050934240EndoSound® EVS SideBeam 5103Endosound, Inc.IYO2026-06-01
00850050934257EndoSound® Coax Transducer Extension Connector (TEC)Endosound, Inc.IYO2026-06-01
00850050934264EndoSound® EVS SideBeam 5105 (4 pouches)Endosound, Inc.IYO2026-06-01
04987670105937DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.IYO2026-06-01
04987670106194DIAGNOSTIC ULTRASOUND SYSTEMCANON INC.IYO2026-06-01
08800013510112L8-17HAlpinion Medical Systems Co., Ltd.IYO2026-05-29
00198953121382VolusonGE Ultrasound Korea Ltd.IYO2026-05-28
08800290066784EVO Q10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-04-03
08800340506147EVO QH10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-04-03
08800340509988EVO XQ10 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-04-03
08800290027471EV2-12SAMSUNG MEDISON CO., LTD.IYO2026-01-28
08800290041767EA2-11AVSAMSUNG MEDISON CO., LTD.IYO2026-01-28
08800290041811EA2-11ARSAMSUNG MEDISON CO., LTD.IYO2026-01-28
08800290042481PA2-9SSAMSUNG MEDISON CO., LTD.IYO2026-01-28
08800290042726CA2-13MSAMSUNG MEDISON CO., LTD.IYO2026-01-28
08800290065473EV2-12SAMSUNG MEDISON CO., LTD.IYO2026-01-28
08800289975974R30 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-01-20
08800289976025R20 Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-01-20
08800289979224EA2-11ARnSAMSUNG MEDISON CO., LTD.IYO2026-01-20
08800289979262CA1-7SnSAMSUNG MEDISON CO., LTD.IYO2026-01-20
08800290027297PA2-9SSAMSUNG MEDISON CO., LTD.IYO2026-01-20
08800290027334LA2-9SnSAMSUNG MEDISON CO., LTD.IYO2026-01-20
08800290027365CA3-10AnSAMSUNG MEDISON CO., LTD.IYO2026-01-20
08800290031522HERA Z20e Diagnostic Ultrasound SystemSAMSUNG MEDISON CO., LTD.IYO2026-01-20
08056304455826MyLabC25ESAOTE SPAIYO2025-12-10
08056304455833MyLabC30ESAOTE SPAIYO2025-12-10
08800290041705miniER7SAMSUNG MEDISON CO., LTD.IYO2025-12-05
08800290041934LA2-9SSAMSUNG MEDISON CO., LTD.IYO2025-12-05
08800290041941CMV1-10SAMSUNG MEDISON CO., LTD.IYO2025-12-05
08800290042184PA1-5ASAMSUNG MEDISON CO., LTD.IYO2025-12-05