Omni Mini

Primary DI
00842078125274
Brand
Omni Mini
Company
EXTREMITY MEDICAL, LLC
Model
154-28116
Device description
Locking Screw – 2.8 x 16mm
Published
2024-07-18
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Single use
true

Product Codes#

Code, Name table
CodeName
HWCScrew, Fixation, Bone

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HWCScrew, Fixation, BoneOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K221362000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K221362000Omni Foot and Ankle Plating SystemExremity Medical, LLC2022-06-10HRS

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
00842078125274PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
00842078125274008420781252748420781252740842078125274

GMDN Terms#

Term, Definition table
TermDefinition
Orthopaedic bone screw (non-sliding)A small, threaded, non-bioabsorbable, implantable rod intended to be used for internal orthopaedic fixation by being screwed into a limb bone, rib, the sternum and/or pelvis to hold a plate, nail, rod or prosthesis to the bone, or to provide direct interfragmentary stabilization of a fractured bone; it is not intended to be introduced through the sleeve of a femoral neck fixation plate/sleeve, or used in dentistry/orthodontics, craniofacial or spinal bones. It is typically of cortical or cancellous design and has a drive (e.g., a slot, or of cross, star, or polygonal shape) at its proximal end for introduction with a screwdriver. It is made of non-bioabsorbable materials (e.g., metal).

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Regulatory Flags#

DUNS number
832720358
Device count
1
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00842078125724Carilaginator168-050102026-06-09
00842078125748Carilaginator168-050202026-06-09
00842078130261Carilaginator170-021412026-06-09
00842078130315Carilaginator170-021402026-06-09
00842078130452Carilaginator170-012512026-06-09
00842078130490Carilaginator170-012502026-06-09
00842078130537Carilaginator170-000112026-06-09
00842078134054Carilaginator168-05010-S2026-06-09
00842078134061Carilaginator168-05020-S2026-06-09
00842078134078Carilaginator170-00011-S2026-06-09
00842078134085Carilaginator170-01250-S2026-06-09
00842078134092Carilaginator170-01251-S2026-06-09
00842078134108Carilaginator170-02140-S2026-06-09
00842078134115Carilaginator170-02141-S2026-06-09
00842078136553MetaFore171-25012-S2026-01-22
00842078136560MetaFore171-25014-S2026-01-22
00842078136577MetaFore171-25016-S2026-01-22
00842078136584MetaFore171-25018-S2026-01-22
00842078136591MetaFore171-25020-S2026-01-22
00842078136607MetaFore171-25022-S2026-01-22

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00889929072745NEXXT MATRIXX® SI SystemNEXXT SPINE, LLCHWC2026-07-17
07613327646825NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646832NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646849NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646856NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646863NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646870NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646887NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646894NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646900NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646917NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646931NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646948NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646955NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646962NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646979NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646986NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327646993NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327647006NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327647013NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327647020NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327647037NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327647044NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
07613327647051NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
37613327647069NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
37613327647076NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
37613327647090NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
37613327647106NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
37613327647113NAStryker Leibinger GmbH & Co. KGHWC2026-07-17
37613327647120NAStryker Leibinger GmbH & Co. KGHWC2026-07-17