FRACTORA

Primary DI
07290016633054
Brand
FRACTORA
Company
INMODE M.D LTD
Model
AG601261A
Catalog number
AG601261A
Device description
Fractora
Published
2016-10-25
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GEIElectrosurgical, Cutting & Coagulation & Accessories

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GEIElectrosurgical, Cutting & Coagulation & AccessoriesGeneral, Plastic Surgery2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K102461000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K102461000FRACTORAInvasix , Ltd.2011-06-02GEI

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
07290016633054PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
07290016633054072900166330547290016633054

GMDN Terms#

Term, Definition table
TermDefinition
Radio-frequency skin surface treatment system applicatorA handpiece component of a radio-frequency skin surface treatment system designed to be used by the system operator to deliver bipolar radio-frequency (RF) energy to the skin surface for skin resurfacing. It is typically designed to deliver RF energy to the skin in a non-homogenous fractional manner, via an array of multi-electrode pins, to leave minimal-impact areas of skin to facilitate healing. The applicator connects with the system?s control unit and may include vacuum to facilitate its coupling with the skin. This is a reusable device.

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure90 KiloPascal110 KiloPascal
Handling Environment Humidity30 Percent (%) Relative Humidity80 Percent (%) Relative Humidity
Handling Environment Temperature15 Degrees Celsius30 Degrees Celsius
Storage Environment Atmospheric Pressure50 KiloPascal110 KiloPascal
Storage Environment Humidity0 Percent (%) Relative Humidity80 Percent (%) Relative Humidity
Storage Environment Temperature-20 Degrees Celsius65 Degrees Celsius

Sterilization Methods#

Method table
Method

Contacts#

Phone, Email table
PhoneEmail
1-887-367-4556contact@InMode.com

Regulatory Flags#

DUNS number
600417351
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
07290019863205Morpheus8 90 ApplicatorAG613133AAG613133A2026-04-19
07290019863212Morpheus8 90 TipAG613135AAG613135A2026-04-19
07290019863410InModeRF hand pieceHP1722B6AHP1722B6A2026-04-16
07290019863274InMode RF hand pieceHP060999AHP060999A2025-02-20
07290019863281InMode RF hand pieceHP101396AHP101396A2025-02-20
07290019863298InMode RF hand pieceHP172296AHP172296A2025-02-20
07290019863083Morpheus8 Resurfacing TIPAG613051AAG613051A2024-08-22
07290019863090Morpheus8 Prime 12 pin TIPAG613052AAG613052A2024-08-22
07290019863106Morpheus8 40 pin TIPAG613053AAG613053A2024-08-22
07290019863113Morpheus8 24 pin TIPAG613054AAG613054A2024-08-22
07290019863120Morpheus8 Burst ApplicatorAG613055AAG613055A2024-08-21
07290019863137Morpheus8 Burst Deep ApplicatorAG613056AAG613056A2024-08-21
07290019863076InModeRF hand pieceHP2539B6AHP2539B6A2024-08-08
07290019863045InMode RF hand pieceHP102206AHP102206A2024-04-25
07290019863052InMode RF hand pieceHP253966AHP253966A2024-04-25
07290019863069InModeRF hand pieceHP1022B6AHP1022B6A2024-08-08
07290019863250Ignite RF SystemAG613237AAG613237A2024-03-24
07290016633689Transform (T3 Applicator) AG609899A AG609899A 2022-10-27
07290016633498Evolve SystemAG608081AAG608081A2022-10-26
07290016633252InModeAG606666AAG606666A2017-03-14

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
B382SD08890310101D0Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD08890320101D0Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD7720520001Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD7720585030Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD84032220032B0Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD8406210032B0Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD89029200Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD89039060Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD89139290Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD8917450Surgical DirectSurgical Direct, Inc.GEI2026-07-14
B382SD89179290Surgical DirectSurgical Direct, Inc.GEI2026-07-14
00848657078399AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-07-10
00848657078405AEDNATIONAL ADVANCED ENDOSCOPY DEVICES, INC.GEI2026-07-10
03665415002710Bipolar electrode UNIV / THIN, extra length (round ; Fr26)LAMIDEY NOURY MEDICALGEI2026-07-10
07613327666878N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666885N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666892N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666908N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666915N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
07613327666922N/ASTRYKER SUSTAINABILITY SOLUTIONS, INC.GEI2026-06-25
00190776421755MillenniumAvalign Technologies, Inc.GEI2026-06-24
00813527028590E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028613E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028637E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028651E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028675E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028699E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028712E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028736E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23
00813527028750E SurgicalNEW DEANTRONICS TAIWAN LTD.GEI2026-06-23