NA

Primary DI
07611819798182
Brand
NA
Company
Synthes GmbH
Model
05.001.059
Catalog number
05001059
Device description
CRANIOTOME ATTACHMENT FOR PEN DRIVE
Published
2016-06-30
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
false
Single use
false

Contact Domains#

Product Codes#

Code, Name table
CodeName
HWEINSTRUMENT, SURGICAL, ORTHOPEDIC, AC-POWERED MOTOR AND ACCESSORY/ATTACHMENT

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HWEInstrument, Surgical, Orthopedic, Ac-Powered Motor And Accessory/AttachmentGeneral, Plastic Surgery1

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K043310000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K043310000SYNTHES (USA) ELECTRIC PEN DRIVE SYSTEMSynthes (Usa)2005-01-05HWE

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
07611819798182Direct MarkingGS10
10886982128836PrimaryGS10
H679050010590SecondaryHIBCC0

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
07611819798182076118197981827611819798182
1088698212883610886982128836

GMDN Terms#

Term, Definition table
TermDefinition
Trephining power tool attachmentA device intended to connect to a surgical power tool system motor [it is locked and held in a collet or quick coupling and not simply gripped in a drill chuck (Jacobs chuck)] to convert the non-dedicated mechanical energy provided by the motor to a dedicated mechanical motion to function as a craniotome when an appropriate cutter is inserted. It is inserted through a pre-drilled bur hole or perforator hole and is used to cut a flap in the bone of the skull vault (calvarium). It includes a small shielding tip at the distal end to prevent the end of the cutter penetrating the dura mater membrane. This is a reusable device.

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1(800)255-2500xx@xx.xx

Regulatory Flags#

DUNS number
486711679
Device count
1
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
false
Expiration date on label
false
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10886982030054LCP02.108.412021084122015-09-14
10886982033079VA-LCP02.112.049021120492015-09-14
10886982042590LCP02.124.213021242132015-09-14
10886982055552NA02.221.002S02221002S2015-09-14
10886982055569NA02.221.003S02221003S2015-09-14
10886982055583NA02.221.004S02221004S2015-09-14
10886982076748NA03.221.015032210152016-12-31
10886982076762NA03.221.016032210162016-12-31
10886982076779NA03.221.017032210172016-12-31
10886982120960NA04.221.002S04221002S2015-09-14
10886982120977NA04.221.003S04221003S2015-09-14
10886982120991NA04.221.004S04221004S2015-09-14
10886982182494NA298.800.01S29880001S2015-09-14
10886982182500NA298.801.01S29880101S2015-09-14
10886982198112NA391.1033911032016-12-31
10886982198129NA391.1043911042016-12-31
10886982198136NA391.1053911052016-12-31
10886982198143NA391.1063911062016-12-31
10886982198150NA391.1073911072016-12-31
10886982198167NA391.1083911082016-12-31

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00842078125724CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078125748CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078130261CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078130315CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078130452CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078130490CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078130537CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078134054CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078134061CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078134078CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078134085CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078134092CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078134108CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00842078134115CarilaginatorEXTREMITY MEDICAL, LLCHWE2026-06-09
00850078396303PFT Adapter, SYK, Virata, 85 in-lb (228-TXRX-006)Eca Medical InstrumentsHWE2026-06-05
00850078396310PFT Adapter, SYK, Mariner, 105 in-lb (228-TXRX-007)Eca Medical InstrumentsHWE2026-06-05
10705034647807TRIALTISMedos International SàrlHWE2026-06-03
10705034647814TRIALTISMedos International SàrlHWE2026-06-03
10705034647821TRIALTISMedos International SàrlHWE2026-06-03
10705034647838TRIALTISMedos International SàrlHWE2026-06-03
10705034648118TRIALTISMedos International SàrlHWE2026-06-03
00810111227292K-WireTreace Medical Concepts, Inc.HWE2026-06-02
07613327648331PANGEAStryker GmbHHWE2026-06-02
07613327648362PANGEAStryker GmbHHWE2026-06-02
07613327652703N/ASTRYKER CORPORATIONHWE2026-04-15
07613327652710PROstepSTRYKER CORPORATIONHWE2026-04-13
07613327652727N/ASTRYKER CORPORATIONHWE2026-04-13
07613327652734N/ASTRYKER CORPORATIONHWE2026-04-13
07613327652741N/ASTRYKER CORPORATIONHWE2026-03-25
07613327652758N/ASTRYKER CORPORATIONHWE2026-03-25