NA

Primary DI
08800019200260
Brand
NA
Company
ECOTRON
Model
Anyview-320DR
Catalog number
ECO-ER-CAT-001DR
Device description
1. Line Voltage: 220~230V, 50/60Hz2. Output Power: 3.2kW3. Fluoroscopy Mode - F-mode: 0.5~10mA - P-mode: 0.5~20mA - Boost mode: 30mA - DS mode: 10~30mA4. Radiography Mode - kV range: 40~110kV, mA range: 15~40mA, mAs range: 0.8~100mAs5. X-ray Tube - XRR-2551(Rotating Type), Focal Spot: 0.3/0.6, Target Angle: 10degree, Anode Heat Storage: 210kHU6. Detector - VIVIX-D 1212G (VIEWORKS), 12 x 12 inch
Published
2018-03-29
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Contact Domains#

Product Codes#

Code, Name table
CodeName
JAASystem, X-Ray, Fluoroscopic, Image-Intensified
OWBInterventional Fluoroscopic X-Ray System
OXOImage-Intensified Fluoroscopic X-Ray System, Mobile

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
JAASystem, X-Ray, Fluoroscopic, Image-IntensifiedRadiology2
OWBInterventional Fluoroscopic X-Ray SystemRadiology2
OXOImage-Intensified Fluoroscopic X-Ray System, MobileRadiology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K180473000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K180473000ANYVIEW DR SERIES FPD Fluoroscopic Mobile C-arm ANYVIEW-240DR, ANYVIEW-320DR, ANYVIEW-500DREcotron Co., Ltd.2018-03-23OWB

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
08800019200260PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, EAN-13 table
Source identifierGTIN-14 normalizedEAN-13
08800019200260088000192002608800019200260

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Height1650Millimeter
Length1852Millimeter
Weight250Kilogram
Width800Millimeter

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature10 Degrees Celsius40 Degrees Celsius
Storage Environment Humidity5 Percent (%) Relative Humidity95 Percent (%) Relative Humidity
Storage Environment Temperature-10 Degrees Celsius70 Degrees Celsius

Contacts#

Phone, Email table
PhoneEmail
9999999999jun1117@ecotron.co.kr

Regulatory Flags#

DUNS number
688209954
Device count
1
Serial number
true
Manufacturing date on label
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
08800019200437N/AProX GoECO-ER-CAT-001Pro2025-03-14
08800019200406N/ADT-703ECO-ER-CAT-001DT2022-07-05
08800019200000NAEPX-F1600ECO-ER-CAT-001P2016-09-28
08800019200017NAEPX-F2400ECO-ER-CAT-001P2016-09-28
08800019200024NAEPX-F2800ECO-ER-CAT-001P2016-09-28
08800019200031NAEPX-F3200ECO-ER-CAT-001P2016-09-28
08800019200048NAEPX-F4000ECO-ER-CAT-001P2016-09-28
08800019200055NAEPX-F5000ECO-ER-CAT-001P2016-09-28
08800019200093NAAnyview-500RECO-ER-CAT-002C2016-11-05
08800019200253NAAnyview-240DRECO-ER-CAT-001DR2018-03-29
08800019200277NAAnyview-500DRECO-ER-CAT-001DR2018-03-29
08800019200123N/ASXG-32RECO-ER-CAT-001S2016-10-27
08800019200130N/ASXG-40RECO-ER-CAT-001S2016-10-27
08800019200147N/ASXG-52RECO-ER-CAT-001S2016-10-27
08800019200154N/ASXG-68RECO-ER-CAT-001S2016-10-27
08800019200161N/ASXG-80RECO-ER-CAT-001S2016-10-27

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00680211003313PREFERRED MEDICAL PRODUCTS LLCPREFERRED MEDICAL PRODUCTS, LLCJAA2026-10-12
00860016243804C-beamPulmera, Inc.OWB2026-10-10
00884838120433SmartCTPhilips Medical Systems Nederland B.V.OWB2026-09-28
00190376649474CONTOUR3DALPHATEC SPINE, INC.OWB2026-09-25
00190376652313CONTOUR3DALPHATEC SPINE, INC.OWB2026-09-25
00190376652320CONTOUR3DALPHATEC SPINE, INC.OWB2026-09-25
00190376652337CONTOUR3DALPHATEC SPINE, INC.OWB2026-09-25
00190376668307CONTOUR3DALPHATEC SPINE, INC.OWB2026-09-25
BN981BN002020Bolt NavigationCircinus Medical Technology LLCOWB2026-09-25
BN981BN00202BX101Bolt NavigationCircinus Medical Technology LLCOWB2026-09-25
00680211003306PREFERRED MEDICAL PRODUCTS LLCPREFERRED MEDICAL PRODUCTS, LLCJAA2026-09-22
00680211003290PREFERRED MEDICAL PRODUCTS LLCPREFERRED MEDICAL PRODUCTS, LLCJAA2026-09-21
00850079606081MC2 Portable X-ray SystemOXOS Medical, Inc.OXO2026-09-21
00850079606081MC2 Portable X-ray SystemOXOS Medical, Inc.OWB2026-09-21
00850079606098EmitterOXOS Medical, Inc.OWB2026-09-21
00850079606098EmitterOXOS Medical, Inc.OXO2026-09-21
00850079606104CassetteOXOS Medical, Inc.OXO2026-09-21
00850079606104CassetteOXOS Medical, Inc.OWB2026-09-21
04547410582901FDR CROSS SlimFUJIFILM CORPORATIONOWB2026-08-14
04547410582901FDR CROSS SlimFUJIFILM CORPORATIONJAA2026-08-14
00854810007199iXRSIcRco, Inc.JAA2026-07-22
00860014944611nView s1 with nav optionNVIEW MEDICAL INC.OXO2026-07-08
00860014944611nView s1 with nav optionNVIEW MEDICAL INC.JAA2026-07-08
00860014944611nView s1 with nav optionNVIEW MEDICAL INC.OWB2026-07-08
00680211003276PREFERRED MEDICAL PRODUCTS LLCPREFERRED MEDICAL PRODUCTS, LLCJAA2026-07-06
00848340021879Mitaka DrapeADVANCE MEDICAL DESIGNS, INC.JAA2026-06-25
05060508110057Cydar MapsCYDAR LIMITEDOWB2026-05-27
08055186671225A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRLA.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRLOXO2026-05-21
08055186671225A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRLA.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRLOWB2026-05-21
08055186671232A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRLA.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRLOXO2026-05-21