Genoray
- Primary DI
- 08809244060090
- Brand
- Genoray
- Company
- GENORAY CO., LTD.
- Model
- ZEN-2090 Turbo
- Published
- 2025-05-02
- Public version status
- New
- Distribution status
- In Commercial Distribution
- MRI safety
- Labeling does not contain MRI Safety Information
Product Codes#
Code, Name table| Code | Name |
|---|
| JAA | System, X-Ray, Fluoroscopic, Image-Intensified |
| OWB | Interventional Fluoroscopic X-Ray System |
| OXO | Image-Intensified Fluoroscopic X-Ray System, Mobile |
Product Code Classifications#
Code, Device, Specialty table| Code | Device | Specialty | Class |
|---|
| JAA | System, X-Ray, Fluoroscopic, Image-Intensified | Radiology | 2 |
| OWB | Interventional Fluoroscopic X-Ray System | Radiology | 2 |
| OXO | Image-Intensified Fluoroscopic X-Ray System, Mobile | Radiology | 2 |
Identifiers And Packaging#
Identifier, Type, Agency table| Identifier | Type | Agency | Package quantity | Status |
|---|
| 08809244060090 | Primary | GS1 | 0 | |
Alternate GTIN / UPC / EAN Codes
Source identifier, GTIN-14 normalized, EAN-13 table| Source identifier | GTIN-14 normalized | EAN-13 |
|---|
| 08809244060090 | 08809244060090 | 8809244060090 |
Regulatory Flags#
- DUNS number
- 631064672
- Device count
- 1
- Serial number
- true
- Manufacturing date on label
- true
Other Devices From This Company#
Other Devices Sharing Product Codes#
Primary DI, Brand, Company table| Primary DI | Brand | Company | Product code | Published |
|---|
| 00680211003313 | PREFERRED MEDICAL PRODUCTS LLC | PREFERRED MEDICAL PRODUCTS, LLC | JAA | 2026-10-12 |
| 00860016243804 | C-beam | Pulmera, Inc. | OWB | 2026-10-10 |
| 00884838120433 | SmartCT | Philips Medical Systems Nederland B.V. | OWB | 2026-09-28 |
| 00190376649474 | CONTOUR3D | ALPHATEC SPINE, INC. | OWB | 2026-09-25 |
| 00190376652313 | CONTOUR3D | ALPHATEC SPINE, INC. | OWB | 2026-09-25 |
| 00190376652320 | CONTOUR3D | ALPHATEC SPINE, INC. | OWB | 2026-09-25 |
| 00190376652337 | CONTOUR3D | ALPHATEC SPINE, INC. | OWB | 2026-09-25 |
| 00190376668307 | CONTOUR3D | ALPHATEC SPINE, INC. | OWB | 2026-09-25 |
| BN981BN002020 | Bolt Navigation | Circinus Medical Technology LLC | OWB | 2026-09-25 |
| BN981BN00202BX101 | Bolt Navigation | Circinus Medical Technology LLC | OWB | 2026-09-25 |
| 00680211003306 | PREFERRED MEDICAL PRODUCTS LLC | PREFERRED MEDICAL PRODUCTS, LLC | JAA | 2026-09-22 |
| 00680211003290 | PREFERRED MEDICAL PRODUCTS LLC | PREFERRED MEDICAL PRODUCTS, LLC | JAA | 2026-09-21 |
| 00850079606081 | MC2 Portable X-ray System | OXOS Medical, Inc. | OXO | 2026-09-21 |
| 00850079606081 | MC2 Portable X-ray System | OXOS Medical, Inc. | OWB | 2026-09-21 |
| 00850079606098 | Emitter | OXOS Medical, Inc. | OWB | 2026-09-21 |
| 00850079606098 | Emitter | OXOS Medical, Inc. | OXO | 2026-09-21 |
| 00850079606104 | Cassette | OXOS Medical, Inc. | OXO | 2026-09-21 |
| 00850079606104 | Cassette | OXOS Medical, Inc. | OWB | 2026-09-21 |
| 04547410582901 | FDR CROSS Slim | FUJIFILM CORPORATION | OWB | 2026-08-14 |
| 04547410582901 | FDR CROSS Slim | FUJIFILM CORPORATION | JAA | 2026-08-14 |
| 00854810007199 | iXRS | IcRco, Inc. | JAA | 2026-07-22 |
| 00860014944611 | nView s1 with nav option | NVIEW MEDICAL INC. | OXO | 2026-07-08 |
| 00860014944611 | nView s1 with nav option | NVIEW MEDICAL INC. | JAA | 2026-07-08 |
| 00860014944611 | nView s1 with nav option | NVIEW MEDICAL INC. | OWB | 2026-07-08 |
| 00680211003276 | PREFERRED MEDICAL PRODUCTS LLC | PREFERRED MEDICAL PRODUCTS, LLC | JAA | 2026-07-06 |
| 00848340021879 | Mitaka Drape | ADVANCE MEDICAL DESIGNS, INC. | JAA | 2026-06-25 |
| 05060508110057 | Cydar Maps | CYDAR LIMITED | OWB | 2026-05-27 |
| 08055186671225 | A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRL | A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRL | OXO | 2026-05-21 |
| 08055186671225 | A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRL | A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRL | OWB | 2026-05-21 |
| 08055186671232 | A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRL | A.T.S. APPLICAZIONE TECNOLOGIE SPECIALI SRL | OXO | 2026-05-21 |