Licox®

Primary DI
10381780121862
Brand
Licox®
Company
INTEGRA LIFESCIENCES (IRELAND) LIMITED
Model
LCX02
Catalog number
LCX02
Device description
Integra® Licox® PtO2 Monitor
Published
2016-12-29
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
MR Unsafe
Rx
true

Contact Domains#

Product Codes#

Code, Name table
CodeName
GWMDEVICE, MONITORING, INTRACRANIAL PRESSURE

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GWMDevice, Monitoring, Intracranial PressureNeurology2

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10381780121862PrimaryGS10
M273LCXO21SecondaryHIBCC0

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized table
Source identifierGTIN-14 normalized
1038178012186210381780121862

GMDN Terms#

Term, Definition table
TermDefinition
Tissue oxygen monitorAn electrically-powered device intended to be used to continuously measure the partial pressure of oxygen (pO2) in tissues during clinical procedures at high risk for tissue hypoxia (e.g., neurosurgery, skin graft surgery) or during patient critical care (e.g., ICU, PACU); some types may in addition measure tissue temperature. It includes controls, display screen, and cables for connection of dedicated tissue-specific sensors (not included). It may have programmable alarms, internal storage, and ports for peripheral devices.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Device Size Text, specify0

Storage And Handling#

Type, Low, High table
TypeLowHighCondition
Handling Environment Atmospheric Pressure700 millibar1060 millibar
Handling Environment Humidity30 Percent (%) Relative Humidity75 Percent (%) Relative Humidity
Handling Environment Temperature15 Degrees Celsius30 Degrees Celsius
Special Storage Condition, Specify00Keep Dry

Contacts#

Phone, Email table
PhoneEmail
+1(800)654-2873custsvcnj@integralife.com

Regulatory Flags#

DUNS number
989925396
Device count
1
Lot or batch
true
No natural rubber latex
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
10381780039570Camino®PMIOMPM1PMIOMPM-12016-12-29
10381780533870CUSA® ClarityC7404SC7404S2023-06-21
10381780533894CUSA® ClarityC7404LSC7404LS2023-06-21
10381780536369CUSA® ClarityC7421SC7421S2022-11-15
10381780536383CUSA® ClarityC7523XC7523X2023-07-14
10381780536376CUSA® ClarityC7523XEAC7523XEA2023-07-14
10381780536352CUSA® ClarityC7421SEAC7421SEA2022-11-15
10381780533863CUSA® ClarityC7404SEAC7404SEA2022-09-06
10381780533887CUSA® ClarityC7404LSEAC7404LSEA2022-09-06
10381780026075CUSA® ExcelC4616SC4616S2016-12-29
10381780026082CUSA® ExcelC4617SC4617S2016-12-29
10381780248248CUSA® ExcelC4604ELTUS2016-12-29
10381780031659CUSA® ExcelC4617SEAC4617SEA2016-12-29
10381780466291Integra®PMIOMPM-1PMIOMPM-12018-05-30
10381780250074Licox®BC10PMOBC10PMO2016-08-02
10381780250043Licox®PMOCABPMOCAB2016-08-02
10381780121893Camino®BAT10012016-12-29
10381780039556Camino®CAMCABL2016-12-29
10381780121886Camino®EXPORTCABEXPORTCAB2016-12-29
10381780121879Camino®MONPWRMONPWR2016-12-29

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
07908398200008BraincareBRAINCARE DESENVOLVIMENTO E INOVACAO TECNOLOGICA SAGWM2026-05-08
00850013266272IRRAflow Cranial Access BoltClearpoint Neuro, Inc.GWM2025-07-24
00763000281243Exacta Pole Clamp with laser levelMEDTRONIC PS MEDICAL, INC.GWM2025-02-17
00763000281229Exacta Pole Clamp with laser levelMEDTRONIC PS MEDICAL, INC.GWM2025-02-16
00763000467401NAMEDTRONIC PS MEDICAL, INC.GWM2024-06-01
00763000406073BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-03-31
20763000467344NAMEDTRONIC PS MEDICAL, INC.GWM2024-03-01
20763000467351NAMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
20763000467382NAMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
20763000467399NAMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000406080NAMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000431259BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000529307BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000529369BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-02-26
00763000572877BeckerMEDTRONIC PS MEDICAL, INC.GWM2024-02-25
00850013266203IRRAflow Tube SetClearpoint Neuro, Inc.GWM2023-11-02
00763000624774Duet®MEDTRONIC PS MEDICAL, INC.GWM2022-03-10
00763000624781Duet®MEDTRONIC PS MEDICAL, INC.GWM2022-03-10
00763000624798Duet®MEDTRONIC PS MEDICAL, INC.GWM2022-03-10
00763000428723Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000428747Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000428754Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000428761Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000428778Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-03-07
00763000431273Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-02-13
20763000431307N/AMEDTRONIC PS MEDICAL, INC.GWM2021-02-07
00763000395971Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-02-07
00763000395988N/AMEDTRONIC PS MEDICAL, INC.GWM2021-02-07
00763000406004Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-02-07
00763000406011Duet®MEDTRONIC PS MEDICAL, INC.GWM2021-02-07