Home GUDID 15420045506909 Discovey C
Primary DI 15420045506909
Brand Discovey C
Company Hologic, Inc.
Model Discovery C
Catalog number DIscovery-Ci
Device description The Discovery series bone densitometers are computer-assisted X-Ray scanners used to aid a physician in measuring bone mineral density (BMD) and determining fracture risk. All Discovery Series densitometers allow comparison of estimated BMD from a subject's proximal femur (hip), lumbar spine, and forearm to reference data for sex and ethnicity matched controls. Discovery Wi, W, and A models can also be used for estimating the lean body mass and fat mass of non-osseous tissues. Discovery C, W, SL, and A models can be used for performing a visual or quantitative assessment of vertebral bodies for diagnosis of vertebral deformity. Discovery SL and A models are capable of measuring the lateral vertebral BMD in the supine lateral position.
Published 2017-11-15
Public version status Update
Distribution status Not in Commercial Distribution
MRI safety MR Unsafe
Rx true
Product Codes# Code, Name table Code Name KGI Densitometer, bone
Product Code Classifications# Code, Device, Specialty table Code Device Specialty Class KGI Densitometer, Bone Radiology 2
Identifiers And Packaging# Identifier, Type, Agency table Identifier Type Agency Package quantity Status 15420045506909 Primary GS1 0
Alternate GTIN / UPC / EAN Codes Source identifier, GTIN-14 normalized table Source identifier GTIN-14 normalized 15420045506909 15420045506909
Storage And Handling# Type, Low, High table Type Low High Condition Handling Environment Temperature 15 Degrees Celsius 32 Degrees Celsius Storage Environment Temperature -30 Degrees Celsius 50 Degrees Celsius
Regulatory Flags# DUNS number 153623137 Device count 1 DM exempt true Serial number true Other Devices From This Company# Other Devices Sharing Product Codes# Primary DI, Brand, Company table Primary DI Brand Company Product code Published 00198953183984 Lunar GE Medical Systems, Ultrasound & Primary Care Diagnostics LLC KGI 2026-10-19 00860016420908 AutoBMD Heart Lung Corporation KGI 2026-09-04 00860016420922 AI-CVD Heart Lung Corporation KGI 2026-09-04 08437021740066 3D-SHAPER 3D-SHAPER MEDICAL S.L. KGI 2026-05-12 B214OSTBSIV400 TBS iNsight medimaps group SA KGI 2025-02-13 08437021740028 3D-SHAPER 3D-SHAPER MEDICAL S.L. KGI 2023-10-04 B052PHCTM40 Model 4 CT Calibration Phantom MINDWAYS SOFTWARE, INC. KGI 2023-05-04 B214OSPTMV30 Phantom medimaps group SA KGI 2022-12-08 B214OSPTM3 Phantom medimaps group SA KGI 2022-12-08 B214OSTBSI3120 TBS iNsight medimaps group SA KGI 2022-01-13 00866955000478 IlluminatusDXA Software Norland at Swissray KGI 2020-07-27 B214OSTBSI3110 TBS iNsight medimaps group SA KGI 2020-06-25 B214OSTBSI3100 TBS iNsight medimaps group SA KGI 2020-02-28 B214OSTBSI303 TBS iNsight medimaps group SA KGI 2018-08-30 00860000233101 VirtuOst O N DIAGNOSTICS LLC KGI 2018-08-15 00840682138345 Prodigy GE Medical Systems, Ultrasound & Primary Care Diagnostics LLC KGI 2018-07-03 00840682138352 Prodigy GE Medical Systems, Ultrasound & Primary Care Diagnostics LLC KGI 2018-07-03 15420045507494 APEX Practice Managment Tool Hologic, Inc. KGI 2018-04-04 00866955000409 XR-600 Basic Norland at Swissray KGI 2017-11-16 00866955000416 XR-600 Clinical Norland at Swissray KGI 2017-11-16 00866955000423 XR-600 Advanced Norland at Swissray KGI 2017-11-16 00866955000430 XR-800 Basic Norland at Swissray KGI 2017-11-16 00866955000447 XR- 800 Clinical Norland at Swissray KGI 2017-11-16 00866955000454 XR-800 Advanced Norland at Swissray KGI 2017-11-16 00866955000461 Elite Norland at Swissray KGI 2017-11-16 15420045506893 Discovery SL Hologic, Inc. KGI 2017-11-15 15420045506916 Discovery W Hologic, Inc. KGI 2017-11-15 15420045506879 Discovery A Hologic, Inc. KGI 2017-09-22 04260491560018 NA Stratec Medizintechnik GmbH KGI 2017-04-26 04260491560025 NA Stratec Medizintechnik GmbH KGI 2017-04-26