Single-Site

Primary DI
30886874112725
Brand
Single-Site
Company
INTUITIVE SURGICAL, INC.
Model
478161
Device description
CANNULA SEAL
Published
2016-07-08
Public version status
Update
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information
Rx
true
OTC
false
Sterile
true
Single use
true

Product Codes#

Code, Name table
CodeName
GCJLaparoscope, general & plastic surgery

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
GCJLaparoscope, General & Plastic SurgeryGastroenterology, Urology2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K152448000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K152448000da Vinci Single-Site Instrument and AccessoriesIntuitive Surgical, Inc.2016-03-09NAY

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
10886874112721PackageGS110In Commercial Distribution
30886874112725PackageGS164In Commercial Distribution
00886874112724PrimaryGS10

Alternate GTIN / UPC / EAN Codes

Source identifier, GTIN-14 normalized, UPC-A table
Source identifierGTIN-14 normalizedUPC-AEAN-13
1088687411272110886874112721
3088687411272530886874112725
00886874112724008868741127248868741127240886874112724

GMDN Terms#

Term, Definition table
TermDefinition
Laparoscopic access cannula seal, single-useA small, sterile device intended to create a seal between a laparoscopic access cannula (not included) and an appropriately sized laparoscopic instrument, to inhibit the leakage of insufflation media [e.g., carbon dioxide (CO2) gas]. It is intended to be fitted directly to the proximal end of the sleeve and is typically available in a variety of sizes appropriate for given sleeve/instrument diameters. This is a single-use device.

Device Sizes#

Type, Value, Unit table
TypeValueUnit
Lumen/Inner Diameter5Millimeter
Lumen/Inner Diameter10Millimeter

Sterilization Methods#

Method table
Method

Regulatory Flags#

DUNS number
938647021
Device count
1
DM exempt
false
Premarket exempt
false
HCT/P
false
Kit
false
Combination product
false
Lot or batch
true
Serial number
false
Manufacturing date on label
false
Expiration date on label
true
Donation ID number
false
Contains natural rubber latex
false
No natural rubber latex
false
Sterilization required before use
false

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
00886874121917Sureform48230B2022-05-11
00886874121924Sureform48230W2022-05-11
00886874121931Sureform48230M2022-05-11
00886874124871Ion Tomosynthesis Board3804562025-11-11
00886874111116EndoWrist;daVinci Si4103222016-08-03
00886874112069EndoWrist4280802016-08-03
00886874112106Single-Site; daVinci Si4280932016-08-03
00886874113707Single-Site4780802016-07-08
00886874113738Single-Site4780932016-08-03
00886874115664Endowrist4804222018-05-04
00886874117309da Vinci Energy4804402019-12-10
00886874120736Force Feedback4751722024-03-21
00886874120743Force Feedback4752052024-03-21
00886874123362da Vinci Energy4805222025-08-14
00886874125649Force Feedback4771722026-03-26
00886874125656Force Feedback4772052026-03-26
00886874125571Force Feedback4761722025-01-29
00886874125588Force Feedback4762052025-01-29
00886874123447EndoWrist SP4301512024-12-09
00886874123454EndoWrist SP4301002024-12-09

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
00190776427931MillenniumAvalign Technologies, Inc.GCJ2026-08-27
00190776428051MillenniumAvalign Technologies, Inc.GCJ2026-08-27
00190776428303MillenniumAvalign Technologies, Inc.GCJ2026-08-27
00190776427429MillenniumAvalign Technologies, Inc.GCJ2026-08-26
04580826928451PENTAX MedicalPENTAX MEDICAL CORPORATIONGCJ2026-08-25
04580826928543PENTAX MedicalPENTAX MEDICAL CORPORATIONGCJ2026-08-25
04580826928581PENTAX MedicalPENTAX MEDICAL CORPORATIONGCJ2026-08-25
04580826928604PENTAX MedicalPENTAX MEDICAL CORPORATIONGCJ2026-08-25
08800035701499CORE-TrocarINCORE CO., LTDGCJ2026-08-25
08800035701505CORE-TrocarINCORE CO., LTDGCJ2026-08-25
08800035701512CORE-TrocarINCORE CO., LTDGCJ2026-08-25
08800035701529CORE-TrocarINCORE CO., LTDGCJ2026-08-25
08800035701536CORE-TrocarINCORE CO., LTDGCJ2026-08-25
08800035701543CORE-TrocarINCORE CO., LTDGCJ2026-08-25
08800035701949CORE-TrocarINCORE CO., LTDGCJ2026-08-25
08800035701956CORE-TrocarINCORE CO., LTDGCJ2026-08-25
08800035701963CORE-TrocarINCORE CO., LTDGCJ2026-08-25
B382SD13448970Surgical DirectSurgical Direct, Inc.GCJ2026-08-21
B382SD16008970Surgical DirectSurgical Direct, Inc.GCJ2026-08-21
B382SD161730Surgical DirectSurgical Direct, Inc.GCJ2026-08-21
B382SD77205052000Surgical DirectSurgical Direct, Inc.GCJ2026-08-21
B382SD77205082000Surgical DirectSurgical Direct, Inc.GCJ2026-08-21
B382SD7720508TS2000Surgical DirectSurgical Direct, Inc.GCJ2026-08-21
B382SD77205252000Surgical DirectSurgical Direct, Inc.GCJ2026-08-21
00190776425883MillenniumAvalign Technologies, Inc.GCJ2026-08-18
00190776425906MillenniumAvalign Technologies, Inc.GCJ2026-08-18
00190776425968MillenniumAvalign Technologies, Inc.GCJ2026-08-18
00190776425975MillenniumAvalign Technologies, Inc.GCJ2026-08-18
00190776426361MillenniumAvalign Technologies, Inc.GCJ2026-08-18
00190776426378MillenniumAvalign Technologies, Inc.GCJ2026-08-18