Surgical Direct

Primary DI
B382SD8553510
Brand
Surgical Direct
Company
Surgical Direct, Inc.
Model
SD855-351
Catalog number
SD855-351
Device description
5.5mm 30° Bronchoscope, Autoclavable, HD, German Made, 490mm Length, Storz Fit
Published
2025-09-16
Public version status
New
Distribution status
In Commercial Distribution
MRI safety
Labeling does not contain MRI Safety Information

Contact Domains#

Product Codes#

Code, Name table
CodeName
HRXArthroscope

Product Code Classifications#

Code, Device, Specialty table
CodeDeviceSpecialtyClass
HRXArthroscopeOrthopedic2

Premarket Submissions#

Submission, Supplement table
SubmissionSupplement
K031972000

Premarket Details#

Submission, Supplement, Device table
SubmissionSupplementDeviceApplicantDecision dateProduct code
K031972000ASAP ARTHROSCOPE MODELS; 10-0001-00, 10-0002-00, 10-0003-00, 10-0004-00, 10-0005-00, 10-0006-00, 10-0007-00, 10-0008-00,Asap Endoscopic Products GmbH2003-09-15HRX

Identifiers And Packaging#

Identifier, Type, Agency table
IdentifierTypeAgencyPackage quantityStatus
B382SD8553510PrimaryHIBCC0

GMDN Terms#

Term, Definition table
TermDefinition
Rigid video laparoscopeAn endoscope with a rigid inserted portion intended for the visual examination and treatment of the organs/structures of the abdominal/retroperitoneal cavity. It is inserted through a dedicated incision made in the abdominal wall during laparoscopy. Images are transmitted by a camera/video system to a monitor for viewing by the user. This is a reusable device.

Sterilization Methods#

Method table
Method
Moist Heat or Steam Sterilization

Contacts#

Phone, Email table
PhoneEmail
+1 (800) 519-3293info@surgicaldirect.com

Regulatory Flags#

DUNS number
124367223
Device count
1
Lot or batch
true
Sterilization required before use
true

Other Devices From This Company#

Primary DI, Brand, Model table
Primary DIBrandModelCatalogPublished
B382SD512531140Surgical DirectSD51253114SD512531142026-02-03
B382SD77321140Surgical DirectSD7732114SD77321142026-02-03
B382SD97321140Surgical DirectSD9732114SD97321142026-02-02
B382SD97321150Surgical DirectSD9732115SD97321152026-02-02
B382SD97331160Surgical DirectSD9733116SD97331162026-02-02
B382SD51531140Surgical DirectSD5153114SD51531142025-12-02
B382SD65331140Surgical DirectSD6533114SD65331142025-12-02
B382SD67511170Surgical DirectSD6751117SD67511172025-06-04
B382SD95321140Surgical DirectSD9532114SD95321142025-06-04
B382SD84531130Surgical DirectSD8453113SD84531132025-04-03
B382SD92422150Surgical DirectSD9242215SD92422152025-03-17
B382SD512531150Surgical DirectSD51253115SD512531152025-03-10
B382SD123200Surgical DirectSD12320SD123202024-12-12
B382SD52321110Surgical DirectSD5232111SD52321112024-08-08
B382SD82421110Surgical DirectSD8242111SD82421112024-08-01
B382SD81531140Surgical DirectSD8153114SD81531142024-03-12
B382SD82131160Surgical DirectSD8213116SD82131162024-03-12
B382SD42531170Surgical DirectSD4253117SD42531172024-02-23
B382SD4810450Surgical DirectSD481045SD4810452024-01-31
B382SD77311150Surgical DirectSD7731115SD77311152023-06-06

Other Devices Sharing Product Codes#

Primary DI, Brand, Company table
Primary DIBrandCompanyProduct codePublished
08809281659387BALEX Bone Expander SystemTaeyeon Medical co.,Ltd.HRX2026-05-11
08809281659301BALEX Bone Expander SystemTaeyeon Medical co.,Ltd.HRX2025-08-22
08809281659325BALEX Bone Expander SystemTaeyeon Medical co.,Ltd.HRX2025-08-22
08809281659370BALEX Bone Expander SystemTaeyeon Medical co.,Ltd.HRX2025-08-22
07613327601695Connected OR HubSTRYKER CORPORATIONHRX2025-06-04
07613327601701SDC4K Information Management SystemSTRYKER CORPORATIONHRX2025-06-04
07613327638448OmnicurveSTRYKER CORPORATIONHRX2024-09-03
08800038059313SYNTH™ STANDARDIMEDICOM CO., LTD.HRX2024-03-25
08800038058187SYNTH™ PLUSIMEDICOM CO., LTD.HRX2024-03-22
08800038058200SYNTH™ PLUSIMEDICOM CO., LTD.HRX2024-03-22
08800038057906MEDINAUT-I(ICD System)IMEDICOM CO., LTD.HRX2024-02-22
08800038057913MEDINAUT-I(ICD System)IMEDICOM CO., LTD.HRX2024-02-22
08800038057920MEDINAUT-I(ICD System)IMEDICOM CO., LTD.HRX2024-02-22
08800038057937MEDINAUT-I(ICD System)IMEDICOM CO., LTD.HRX2024-02-22
08800038057944MEDINAUT-I(ICD System)IMEDICOM CO., LTD.HRX2024-02-22
07613327554649OmnicurveSTRYKER CORPORATIONHRX2023-11-02
08800038056305SYNTH™ BESIMEDICOM CO., LTD.HRX2023-10-31
08800038056312SYNTH™ BESIMEDICOM CO., LTD.HRX2023-10-31
08800038056329SYNTH™ BESIMEDICOM CO., LTD.HRX2023-10-31
08800038056336SYNTH™ BESIMEDICOM CO., LTD.HRX2023-10-31
08800038056343SYNTH™ CDSIMEDICOM CO., LTD.HRX2023-10-31
08800038056145SYNTH™ BESIMEDICOM CO., LTD.HRX2023-10-19
08800038056152SYNTH™ BESIMEDICOM CO., LTD.HRX2023-10-19
08800038056169SYNTH™ BESIMEDICOM CO., LTD.HRX2023-10-19
08800038056176SYNTH™ BESIMEDICOM CO., LTD.HRX2023-10-19
08800038056183SYNTH™ CDSIMEDICOM CO., LTD.HRX2023-10-19
08800038055643SYNTH™ STANDARDIMEDICOM CO., LTD.HRX2023-08-30
08800104089473Tracker Plus Kyphoplasty SystemGS Medical Co., Ltd.HRX2022-10-24
08800104089480Tracker Plus Kyphoplasty SystemGS Medical Co., Ltd.HRX2022-10-24
07613327554663OmnicurveSTRYKER CORPORATIONHRX2022-04-12