W/CLIP PDQ INSTANT HAND SANITIZER
Ethyl Alcohol
81 matching records for CLIP 9.
Ethyl Alcohol
ALCOHOL
Ethyl Alcohol
Ethyl Alcohol
ALCOHOL
ALCOHOL
ALCOHOL
Instant Hand Sanitizer with Security Clip
ALCOHOL
Ethyl Alcohol
Ethyl Alcohol
ALCOHOL
ALCOHOL
Alcohol
Alcohol
Alcohol
ALCOHOL
ethyl alcohol
ALCOHOL
ALCOHOL
ALCOHOL
ALCOHOL
ALCOHOL
ALCOHOL
ALCOHOL
ALCOHOL
ALCOHOL
60% Alcohol Sanitizer
70% Alcohol Sanitizer with Chlorhexidine Gluconate
ALCOHOL
20250408
20250213
20231121
20231026
20231026
20231026
20211203
20201016
20180725
2026-03-26
2026-03-26
2026-03-25
2026-03-21
2025-07-10
2025-02-01
2024-10-31
2024-06-08
2024-06-08
2024-06-06
2024-06-01
2023-10-26
A small, nonimplantable device in the form of a U-shaped clip that is fired from a dedicated scalp-clip applier (clip gun) or manually applied using dedicated scalp clip forceps, to approximate the margins of a scalp wound/incision associated with a surgica...
A device designed to hold sterile ligation clip cartridges to facilitate quick reloading of the cartridges into a surgical clip applier during a surgical procedure. It is typically made of metal and plastic materials in the form of a flat and stable base wi...
A sterile electrical conductor designed to transmit electric signals from the foetal scalp to an intrapartum monitor. The device is a metallic clip electrode mounted on a small disk with a cable that may include a transducer. The clip is spring-loaded in a ...
A non-sterile length of flexible tubing and associated items intended to be used with surgical hair clippers as a component of a surgical hair clippers suction system, during removal/collection of cut hair through suction, typically as part of hair removal ...
A sterile device intended to be used in combination with a generator to remove a gastrointestinal endoscopic clip. It consists of an insulated conducting wire with an exposed tip intended to be passed through the working channel of an endoscope. It is inten...
A non-sterile, manual device designed to compress a piece of medical device tubing or tubular container to reversibly occlude its lumen and stop the flow of material within; it is not intended for patient-contact. It has a manual mechanism (e.g., hinging, r...
A device typically designed as a container used to hold and protect implantable clips during the sterilization process. The rack also serves to hold the clips in the proper geometric orientation to permit mating with the clip applier used during the clip's ...
A non-sterile, manual device designed to compress a piece of medical device tubing to reversibly occlude its lumen and stop the flow of material within; it is not intended for patient-contact. It has a manual mechanism (e.g., hinging, roller-type, vice-like...
A manual device designed to compress a piece of medical device tubing or tubular container to reversibly occlude its lumen and stop the flow of material within; it is not intended for patient-contact. It has a manual mechanism (e.g., hinging, roller-type, v...
A non-bioabsorbable metallic clip intended to be implanted following a percutaneous catheterization procedure to close the punctured access site on an artery (typically femoral) and improve haemostasis. It is typically a small circular clip with grasping bl...
A non-bioabsorbable metallic clip intended to be implanted following a percutaneous catheterization procedure to close the punctured access site on an artery (typically femoral) and improve haemostasis. It is typically a small circular clip with grasping bl...
A manual device designed to compress a piece of medical device tubing to reversibly occlude its lumen and stop the flow of material within; it is not intended for patient-contact. It has a manual mechanism (e.g., hinging, roller-type, vice-like) whereby pre...
A non-sterile, small, metallic or plastic, clip-like device designed to irreversibly (permanently) compress a piece of medical device tubing to occlude its lumen and stop the flow of material within; it is not intended for patient-contact. It is intended to...
A collection of sterile devices, which includes an implantable haemostatic ligation clip, intended to be used to obtain a full-thickness tissue biopsy and/or therapeutic resection of gastric, duodenal, colonic, and/or rectal tissue during an endoscopic proc...
A portable, mains electricity (AC-powered) device intended to be used in conjunction with a cutter for the endoscopic removal of a gastrointestinal endoscopic clip. It is an electronic unit with controls (e.g., foot-switch) intended to generate a direct cur...
A hand-held manual surgical instrument designed to apply small atraumatic clips (not included) for the ligation of blood vessels, or similar tubular anatomy, mainly to prevent and/or stop bleeding (i.e., haemostasis) during an open-surgery procedure. It may...
A sterile clip intended to be placed short-term (
A metallic, non-bioabsorbable clasp designed to be implanted around a blood vessel, lymphatic vessel, other tubular anatomy or a tissue bundle, for permanent occlusion. It may be used for ligation in open and endoscopic (e.g., laparoscopic) surgeries; a ded...
A sterile, metallic, non-bioabsorbable clasp designed to be implanted around a blood vessel, lymphatic vessel, other tubular anatomy or a tissue bundle, for permanent occlusion. It may be used for ligation in open and endoscopic (e.g., laparoscopic) surgeri...
A non-bioabsorbable clip intended to be implanted long-term (>30 days) within the gastrointestinal (GI) tract during an endoscopic procedure for endoscopic marking, haemostasis, tissue approximation, closure of luminal perforations, treating mucosal/submuco...
A hand-held manual surgical instrument designed to apply small atraumatic clips for the ligation of blood vessels, or similar tubular anatomy, mainly to prevent and/or stop bleeding (i.e., haemostasis) during an open-surgery procedure. It may also be used t...
A scissors- or tweezers-like surgical instrument with two blades joined at their proximal end or midpoint intended to be used to for grasping, opening, and removing a tissue clip. This is a reusable device.
A non-metallic, non-bioabsorbable clasp designed to be implanted around a blood vessel or a tissue bundle for permanent occlusion. It is typically made of plastic materials [e.g., polyoxymethylene (POM), commonly known as Delrin] and may be designed with a ...
A non-sterile, non-surgically invasive device intended to be used to secure a nasogastric tube to the nose of a patient to prevent displacement or removal of the tube. It includes a strap, a clip, and typically devices intended to assist nasal introduction ...
A non-bioabsorbable clip intended to be implanted long-term (>30 days) within the gastrointestinal (GI) tract during an endoscopic procedure for endoscopic marking, haemostasis, tissue approximation, closure of luminal perforations, and/or for treating muco...
A manual, clip-like, surgical device designed specifically to clamp tissues of the gastrointestinal tract (e.g., colon) during open surgery; it does not have handles (i.e., not forceps-like) and is not intended for general manipulation/dissection of tissues...
A hand-held, manually-operated, surgical instrument used to manually apply and remove haemostatic scalp clips (reusable or single-use) from the scalp during or after a surgical intervention on the cranium/scalp. It is typically a scissors-like device with r...
A device intended to hold, position, and organize medical/surgical interventional tubing (e.g., arterial/venous lines, gas lines, drainage catheters, irrigation tubing) or cables to an equipment, drape or gown; it is not intended to affix the tubing to the ...
A sterile, non-metallic, non-bioabsorbable clasp designed to be implanted around a blood vessel or a tissue bundle for permanent occlusion. It is typically made of plastic materials [e.g., polyoxymethylene (POM), commonly known as Delrin] and may be designe...
A small, manually-operated and applied surgical device used to stop bleeding from the scalp during surgery on the cranium. It is is usually applied to the scalp using the fingers or a dedicated pair of scalp clip forceps, and consists of two blades that are...