FDA label 5a88d54e-91bc-4466-924e-5c622bcbe37a
openFDA label record#
This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.
Verified complete openFDA source JSON
- SPL set ID
- ba8fcebf-a924-488f-983d-088892761f0e
- SPL ID
- 5a88d54e-91bc-4466-924e-5c622bcbe37a
- Version
- 6
- Effective date
- 2011-06-17
- Source export date
- 2026-10-12
- Source partition
- 11
- Source file
- https://download.open.fda.gov/drug/label/drug-label-0011-of-0014.json.zip
- Source object key
- raw/openfda/drug-label/2026-10-12/a497e765d824a2e2aa9e88d5f0eea2aae9dcba363989e5f163395cda5c3c9dd8/drug-label-0011-of-0014.json.zip
- Source manifest SHA-256
- 7e6b178df8f32cac9a78e0f5d09c588344509b04fe41effb1dde9102e2a45be6
- Import run
- 20261013T011858Z
- Imported at
- 2026-10-13 02:48:31
Harmonized identifier links#
Every typed identifier imported from the complete openFDA harmonization object is paginated here; values are not reduced to a first match.
| Type | Scope | Identifier | Source field |
|---|---|---|---|
| spl id | 5a88d54e-91bc-4466-924e-5c622bcbe37a | id | |
| spl set id | ba8fcebf-a924-488f-983d-088892761f0e | set_id |
Boxed warning cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
The use of topical bovine thrombin preparations has occasionally been associated with abnormalities in hemostasis ranging from asymptomatic alterations in laboratory determinations, such as prothrombin time (PT) and partial thromboplastin time (PTT), to severe bleeding or thrombosis which rarely have been fatal. These hemostatic effects appear to be related to the formation of antibodies against bovine thrombin and/or factor V which in some cases may cross react with human factor V, potentially resulting in factor V deficiency. Repeated clinical applications of topical bovine thrombin increase the likelihood that antibodies against thrombin and/or factor V may be formed. Consultation with an expert in coagulation disorders is recommended if a patient exhibits abnormal coagulation laboratory values, abnormal bleeding, or abnormal thrombosis following the use of topical thrombin. Any interventions should consider the immunologic basis of this condition. Patients with antibodies to bovine thrombin preparations should not be re-exposed to these products.
Warnings cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
warnings
WARNING The use of topical bovine thrombin preparations has occasionally been associated with abnormalities in hemostasis ranging from asymptomatic alterations in laboratory determinations, such as prothrombin time (PT) and partial thromboplastin time (PTT), to severe bleeding or thrombosis which rarely have been fatal. These hemostatic effects appear to be related to the formation of antibodies against bovine thrombin and/or factor V which in some cases may cross react with human factor V, potentially resulting in factor V deficiency. Repeated clinical applications of topical bovine thrombin increase the likelihood that antibodies against thrombin and/or factor V may be formed. Consultation with an expert in coagulation disorders is recommended if a patient exhibits abnormal coagulation laboratory values, abnormal bleeding, or abnormal thrombosis following the use of topical thrombin. Any interventions should consider the immunologic basis of this condition. Patients with antibodies to bovine thrombin preparations should not be re-exposed to these products. Because of its action in the clotting mechanism, THROMBIN-JMI ® must not be injected or otherwise allowed to enter large blood vessels. Extensive intravascular clotting and even death may result .
Adverse reactions cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
adverse reactions
ADVERSE REACTIONS Allergic reactions may be encountered in persons known to be sensitive to bovine materials. Inhibitory antibodies which interfere with hemostasis may develop in a small percentage of patients. See WARNING .
Reported adverse events (FAERS/openFDA)#