Dextrose
openFDA label record#
This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.
Verified complete openFDA source JSON
- Brand name
- Dextrose
- Generic name
- DEXTROSE
- Manufacturer
- ICU Medical Inc.
- Product type
- HUMAN PRESCRIPTION DRUG
- SPL set ID
- b5cb7a5a-bbe8-4217-a82e-da818f7771c9
- SPL ID
- 98e136db-75df-429c-8d33-03bfae8f511e
- Version
- 8
- Effective date
- 2025-11-02
- Source export date
- 2026-09-28
- Source partition
- 12
- Source file
- https://download.open.fda.gov/drug/label/drug-label-0012-of-0014.json.zip
- Source object key
- raw/openfda/drug-label/2026-09-28/663999d0fe1757c1e2cd13a4799d76d875f663e0bc57701092264ebe7febfc18/drug-label-0012-of-0014.json.zip
- Source manifest SHA-256
- cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
- Import run
- 20260929T050834Z
- Imported at
- 2026-09-29 06:27:45
| Harmonized routes |
|---|
| INTRAVENOUS |
Harmonized identifier links#
Every typed identifier imported from the complete openFDA harmonization object is paginated here; values are not reduced to a first match.
| Type | Scope | Identifier | Source field |
|---|---|---|---|
| application applno | NDA | 018563 | derived:openfda.application_number |
| application applno | NDA | 018562 | derived:openfda.application_number |
| application applno | NDA | 018564 | derived:openfda.application_number |
| application applno | NDA | 018561 | derived:openfda.application_number |
| application applno | NDA | 019345 | derived:openfda.application_number |
| application number | NDA019345 | openfda.application_number | |
| application number | NDA018564 | openfda.application_number | |
| application number | NDA018563 | openfda.application_number | |
| application number | NDA018561 | openfda.application_number | |
| application number | NDA018562 | openfda.application_number | |
| brand name | Dextrose | openfda.brand_name | |
| generic name | DEXTROSE | openfda.generic_name | |
| manufacturer name | ICU Medical Inc. | openfda.manufacturer_name | |
| ndc | package | 0990-7937-19 | openfda.package_ndc |
| ndc | package | 0990-7918-19 | openfda.package_ndc |
| ndc | package | 0990-7936-19 | openfda.package_ndc |
| ndc | package | 0990-7935-19 | openfda.package_ndc |
| ndc | package | 0990-8004-15 | openfda.package_ndc |
| ndc | product | 0990-7935 | openfda.product_ndc |
| ndc | product | 0990-7936 | openfda.product_ndc |
| ndc | product | 0990-7937 | openfda.product_ndc |
| ndc | product | 0990-8004 | openfda.product_ndc |
| ndc | product | 0990-7918 | openfda.product_ndc |
| ndc11 | package | 00990793719 | derived:openfda.package_ndc |
| ndc11 | package | 00990793519 | derived:openfda.package_ndc |
| ndc11 | package | 00990800415 | derived:openfda.package_ndc |
| ndc11 | package | 00990791819 | derived:openfda.package_ndc |
| ndc11 | package | 00990793619 | derived:openfda.package_ndc |
| rxcui | 237650 | openfda.rxcui | |
| rxcui | 242694 | openfda.rxcui | |
| rxcui | 237649 | openfda.rxcui | |
| rxcui | 1795518 | openfda.rxcui | |
| rxcui | 237656 | openfda.rxcui | |
| spl id | 98e136db-75df-429c-8d33-03bfae8f511e | id | |
| spl set id | b5cb7a5a-bbe8-4217-a82e-da818f7771c9 | set_id | |
| unii | LX22YL083G | openfda.unii |
Warnings cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
5 WARNINGS AND PRECAUTIONS • Hyperglycemia or Hyperosmolar Hyperglycemic State : Monitor blood glucose and administer insulin as needed ( 5.1 ) • Hypersensitivity Reactions : Monitor for signs and symptoms and discontinue infusion if reactions occur ( 5.2 ) • Risk of Infection : Monitor for signs and symptoms and laboratory parameters ( 5.3 ) • Refeeding Syndrome : Monitory laboratory parameters ( 5.4 ) • Vein Damage and Thrombosis : Administer solutions containing more than 5% dextrose as the final concentration or solutions with an osmolarity ≥ 900 mOsm/L through a central vein ( 2.1 , 5.5 ) • Aluminum Toxicity : Dextrose Injection contains aluminum that may be toxic. Patients with impaired renal function, and preterm infants, at higher risk. Limit aluminum to less than 4 mcg/kg/day ( 5.6 , 8.4 ) • Parenteral Nutrition Associated Liver Disease : increased risk in patients who receive parenteral nutrition for extended periods of time, especially preterm infants; monitor liver function tests, if abnormalities occur consider discontinuation or dosage reduction. ( 5.7 , 8.4 ) • Electrolyte Imbalance and Fluid Overload : monitor daily fluid balance, blood electrolyte levels, correct as needed. ( 5.8 , 8.4 ) 5.1 Hyperglycemia and Hyperosmolar Hyperglycemic State The use of dextrose infusions in patients with diabetes mellitus or impaired glucose tolerance may worsen hyperglycemia. Administration of dextrose at a rate exceeding the patient's utilization rate may lead to hyperglycemia, coma, and death. Patients with underlying confusion and renal impairment who receive dextrose infusions, may be at greater risk of developing hyperosmolar hyperglycemic state. Monitor blood glucose levels and treat hyperglycemia to maintain optimum levels while administering Dextrose Injection. Insulin may be administered or adjusted to maintain optimal blood glucose levels during Dextrose Injection administration. 5.2 Hypersensitivity Reactions Hypersensitivity reactions including anaphylaxis have been reported with dextrose infusions. Stop infusion immediately and treat patient accordingly if signs or symptoms of a hypersensitivity reaction develop. Signs or symptoms may include: tachypnea, dyspnea, hypoxia, bronchospasm, tachycardia, hypotension, cyanosis, vomiting, nausea, headache, sweating, dizziness, altered mentation, flushing, rash, urticaria, erythema, pyrexia, and chills. 5.3 Risk of Infections Patients who require parenteral nutrition are at high risk of infections because the nutritional components of these solutions can support microbial growth. The risk of infection is increased in patients with malnutrition-associated immunosuppression, hyperglycemia exacerbated by dextrose infusion, long-term use and poor maintenance of intravenous catheters, or immunosuppressive effects of other concomitant conditions, drugs, or other components of the parenteral formulation (e.g., lipid emulsion). To decrease the risk of infectious complications, ensure aseptic technique in catheter placement and maintenance, as well as aseptic technique in the preparation and administration of the nutritional formula. Monitor for signs and symptoms (including fever and chills) of early infections, including laboratory test results (including leukocytosis and hyperglycemia) and frequent checks of the parenteral access device and insertion site for edema, redness and discharge. 5.4 Refeeding Syndrome Refeeding severely undernourished patients may result in refeeding syndrome, characterized by the intracellular shift of potassium, phosphorus, and magnesium as the patient becomes anabolic. Thiamine deficiency and fluid retention may also develop. To prevent these complications, monitor severely undernourished patients and slowly increase nutrient intakes. 5.5 Vein Damage and Thrombosis Dextrose Injection is for admixture with amino acids or dilution with other compatible intravenous fluids. It is not for direct intravenous infusion. Administer solutions containing more than 5% dextrose or with an osmolarity of ≥ 900 mOsm/L through a central vein [see Dosage and Administration ( 2.1 )] . The infusion of hypertonic solutions into a peripheral vein may result in vein irritation, vein damage, and/or thrombosis. The primary complication of peripheral access is venous thrombophlebitis, which manifests as pain, erythema, tenderness or a palpable cord. Remove the catheter as soon as possible, if thrombophlebitis develops. 5.6 Aluminum Toxicity Dextrose Injection contains no more than 25 mcg/L of aluminum. However, with prolonged parenteral administration in patients with renal impairment, the aluminum contained in Dextrose Injection may reach toxic levels. Preterm infants are at greater risk because their kidneys are immature, and they require large amounts of concomitant calcium and phosphate solutions that contain aluminum. Patients with renal impairment, including preterm infants, who receive parenteral levels of aluminum at greater than 4 to 5 mcg/kg/day, accumulate aluminum at levels associated with central nervous system and bone toxicity. Tissue loading may occur at even lower rates of administration of total parenteral nutrition products. 5.7 Risk of Parenteral Nutrition Associated Liver Disease Parenteral Nutrition Associated Liver Disease (PNALD) has been reported in patients who receive parenteral nutrition for extended periods of time, especially preterm infants, and can present as cholestasis or steatohepatitis. The exact etiology is not entirely clear and is likely multifactorial. If Dextrose Injection-treated patients develop abnormal liver function tests consider discontinuation or dosage reduction. 5.8 Electrolyte Imbalance and Fluid Overload Electrolyte deficits, particularly in serum potassium and phosphate, may occur during prolonged use of concentrated dextrose solutions. Depending on the volume and rate of infusion, the intravenous administration of concentrated dextrose solutions can cause fluid and/or solute overloading resulting in dilution of serum electrolyte concentrations, overhydration, congested states or pulmonary edema. The risk of dilutional states is inversely proportional to the electrolyte concentrations in the administered solution. The risk of solute overload causing congested states with peripheral and pulmonary edema is directly proportional to the electrolyte concentrations in the solution. Monitor blood electrolyte levels, correct fluid and electrolyte imbalances, and administer essential vitamins and minerals as needed. Monitor daily fluid balance.
Adverse reactions cross-check#
openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.
adverse reactions
6 ADVERSE REACTIONS The following adverse reactions from voluntary reports or clinical studies have been reported with Dextrose Injection. Because many of these reactions were reported voluntarily from a population of uncertain size, it is not always possible to reliably estimate their frequency or establish a causal relationship to drug exposure. • Hyperglycemia and hyperosmolar hyperglycemic state [see Warnings and Precautions ( 5.1 )] . • Hypersensitivity reactions [see Warnings and Precautions ( 5.2 )] . • Risk of infections [see Warnings and Precautions ( 5.3 )] . • Refeeding syndrome [see Warnings and Precautions ( 5.4 )] . • Vein damage and thrombosis [see Warnings and Precautions ( 5.5 )] . • Aluminum toxicity [see Warnings and Precautions ( 5.6 )] . • Risk of parenteral nutrition associated liver disease [see Warnings and Precautions ( 5.7 )] . • Electrolyte imbalance and fluid overload [see Warnings and Precautions ( 5.8 )] . The most common adverse reactions are hyperosmolar syndrome, infection both systemic and at the injection site, vein thrombosis or phlebitis, and hypervolemia. ( 6 ) To report SUSPECTED ADVERSE REACTIONS, contact ICU Medical, Inc. at 1-800-441-4100, or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch .
Reported adverse events (FAERS/openFDA)#
Adverse event summaries are temporarily unavailable. Other product information remains available.