DRAXIMAGE DTPA

openFDA label record#

This page contains supplementary openFDA label data. For the canonical label presentation, use the corresponding DailyMed Structured Product Label.

Verified complete openFDA source JSON (canonical bytes are SHA-256 checked before publication)

Brand name
DRAXIMAGE DTPA
Generic name
KIT FOR THE PREPARATION OF TECHNETIUM TC 99M PENTETATE
Manufacturer
Jubilant DraxImage Inc., dba Jubilant Radiopharma
Product type
HUMAN PRESCRIPTION DRUG
SPL set ID
becdab53-f7a7-7280-6930-21f3a61b99e7
SPL ID
ea90e623-af26-4014-a0c3-3fe5d753a5e6
Version
8
Effective date
2023-05-08
Source export date
2026-09-28
Source partition
13
Source file
https://download.open.fda.gov/drug/label/drug-label-0013-of-0014.json.zip
Source object key
raw/openfda/drug-label/2026-09-28/e78bf8aa9f90ab13e640d254dfbd4fe5bfeca4995ec5f9d51bce3356e249cab7/drug-label-0013-of-0014.json.zip
Source manifest SHA-256
cd2e66336a5cd2223fa3995098fdbdb84c6a7ee5c0a4addb236ccb22dd1e6887
Import run
20260929T050834Z
Imported at
2026-09-29 06:34:40
Harmonized routes table
Harmonized routes
INTRAVENOUS, RESPIRATORY (INHALATION)

Warnings cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Warnings sections page 1 of 1 · 1 matching rows.

warnings and cautions

5 WARNINGS AND PRECAUTIONS Hypersensitivity reactions: Hypersensitivity reactions, including anaphylaxis, have been reported during post-approval diagnostic use of Technetium Tc 99m pentetate injection. Monitor all patients for hypersensitivity reactions ( 5.1 ). Image interpretation risks in lung ventilation studies: If proximal airway deposition is observed, consider additional diagnostic options ( 5.2 ). Radiation exposure risk: Technetium Tc 99m pentetate contributes to a patient’s overall long-term radiation exposure ( 2.1 , 2.3 , 5.3 ). Bronchospasm in lung ventilation studies: Inhalation of Technetium Tc 99m pentetate solution may result in acute bronchoconstriction, especially in patients with heightened bronchoreactivity ( 5.4 ). 5.1 Hypersensitivity Reactions Hypersensitivity reactions, including anaphylaxis, have been reported during post-approval diagnostic use of Technetium Tc 99m pentetate injection. Monitor all patients for hypersensitivity reactions and have access to cardiopulmonary resuscitation equipment and personnel. 5.2 Image Interpretation Risks in Lung Ventilation Studies In patients with obstructive pulmonary disease there may be deposition of particles in the proximal airways influencing image quality and interfering with diagnostic interpretation, therefore to ensure diagnostic quality, careful use of the nebulizer to assure optimal particle delivery is essential. If interfering particle deposition occurs, consider additional diagnostic options. 5.3 Radiation Exposure Risk Technetium Tc 99m contributes to a patient’s overall long-term cumulative radiation exposure. Long-term cumulative radiation exposure is associated with an increased risk of cancer. Ensure safe handling and preparation procedures to protect patients and health care workers from unintentional radiation exposure. Use the lowest dose of Technetium Tc 99m pentetate necessary for imaging. Encourage patients to drink fluids and void as frequently as possible after intravenous administration [see Dosage and Administration ( 2.1 , 2.3 )] . Radiation risks associated with the use of Technetium Tc 99m pentetate are greater in pediatric patients than in adults due to greater radiosensitivity and longer life expectancy. 5.4 Bronchospasm in Lung Ventilation Studies As with other inhaled medications, inhalation of Technetium Tc 99m pentetate solution may result in acute bronchoconstriction, especially in patients with heightened bronchoreactivity, such as patients with asthma or other lung or allergic disorders. Monitor all patients for bronchoconstriction.

Adverse reactions cross-check#

openFDA text is shown for search and cross-checking; DailyMed SPL is canonical.

Adverse reactions sections page 1 of 1 · 1 matching rows.

adverse reactions

6 ADVERSE REACTIONS The following adverse reactions have been identified post-approval. Because these reactions are voluntarily reported from a population of uncertain size, it is not always possible to reliably estimate their exact frequency or establish a causal relationship to Technetium Tc 99m pentetate exposure. Adverse reactions are presented in decreasing order of reported frequency: Immune system disorders: allergic reaction, anaphylactic reaction, angioedema. Skin and subcutaneous tissue disorders: rash, itching, hives, erythema. Respiratory, thoracic and mediastinal disorders: throat irritation, wheezing. Vascular disorders: hypotension, hypertension. Nervous system disorders: headache, fainting, dizziness. General disorders and administration site conditions: chills. Gastrointestinal disorders: nausea, vomiting. Cardiac disorders: cyanosis, tachycardia. Most common adverse reactions reported with Technetium Tc 99m pentetate injection include allergic reactions, rash, itching ( 6 ). To report SUSPECTED ADVERSE REACTIONS, contact Jubilant DraxImage Inc. at 1-888-633-5343 or FDA at 1-800-FDA-1088 or www.fda.gov/medwatch .

Reported adverse events (FAERS/openFDA)#

Adverse event summaries are temporarily unavailable. Other product information remains available.