QCT PRO 3D Volumetric Spine and CTXA Hip System QCTPROM3SSH

GUDID B052QCTPROM3SSH0

Convenience Kit consisting of - QCT Bone Mineral Density Analysis Software - CTXA Hip Bone Mineral Densitometer - CTXA Hip Extended Reference Database

MINDWAYS SOFTWARE, INC.

CT system application software CT system application software
Primary Device IDB052QCTPROM3SSH0
NIH Device Record Keyfd3f2807-6059-4b11-86c4-73e5ece2ee1f
Commercial Distribution StatusIn Commercial Distribution
Brand NameQCT PRO 3D Volumetric Spine and CTXA Hip System
Version Model NumberK894854K002113K030330
Catalog NumberQCTPROM3SSH
Company DUNS964202592
Company NameMINDWAYS SOFTWARE, INC.
Device Count1
DM Exemptfalse
Pre-market Exemptfalse
MRI Safety StatusLabeling does not contain MRI Safety Information
Human Cell/Tissue Productfalse
Device Kittrue
Device Combination Productfalse
Single Usefalse
Lot Batchtrue
Serial Numbertrue
Manufacturing Datefalse
Expiration Datefalse
Donation Id Numberfalse
Contains Natural Rubber Latexfalse
Labeled No Natural Rubber Latexfalse
RX Perscriptiontrue
OTC Over-The-Counterfalse

Customer Support Contacts

Phone+1 512 912-0871
Emailinfo@qct.com
Phone+1 512 912-0871
Emailinfo@qct.com

Operating and Storage Conditions

Handling Environment TemperatureBetween -40 Degrees Celsius and 60 Degrees Celsius
Handling Environment TemperatureBetween -40 Degrees Celsius and 60 Degrees Celsius

Device Identifiers

Device Issuing AgencyDevice ID
HIBCCB052QCTPROM3SSH0 [Primary]

FDA Pre-market Approvals/Notifications & deNovo

FDA Product Code

KGIDensitometer, Bone

Sterilization

Steralize Prior To Usefalse
Device Is Sterilefalse

Device Entry Metadata

Public Version StatusUpdate
Device Record StatusPublished
Public Version Number3
Public Version Date2018-07-06
Device Publish Date2017-03-31

Devices Manufactured by MINDWAYS SOFTWARE, INC.

B052PHCTM40 - Model 4 CT Calibration Phantom2023-05-12 Calibration phantom intended for use as an accessory to the QCT Pro Bone Mineral Densitometry Software.
B052DIASYNC0 - QCT Pro Asynchronous Calibration Module, CliniQCT2018-07-06 The QCT Pro Asynchronous Calibration Module is intended to provide an alternative method for calibrating QCT data sets that are
B052DICTXAHIP0 - CTXA Hip Bone Mineral Densitometer2018-07-06 The CTXA Hip Bone Mineral Densitometer (CTXA Hip) is a software package intended for estimation of bone mineral content (BMC), i
B052DICTXAHIPEXTDB0 - CTXA Hip Extended Reference Data2018-07-06 The CTXA Hip Extended Reference Data is an accessory to the CTXA Hip Bone Mineral Densitometer. The CTXA Hip Extended Reference
B052DIQCTPRO0 - QCT Bone Mineral Density Analysis Software2018-07-06 The method of Quantitative Computed Tomography (QCT) has been established as a means of non-invasive quantitative bone mineral d
B052QCTPROM0AS0 - QCT PRO Asynchronous 3D Spine Software2018-07-06 Convenience Kit consisting of - QCT Pro Asynchronous Calibration Module, CliniQCT - QCT Bone Mineral Density Analysis Software -
B052QCTPROM0ASH0 - QCT PRO Asynchronous 3D Spine and CTXA-Hip Softwar2018-07-06 Convenience Kit consisting of - QCT Pro Asynchronous Calibration Module, CliniQCT - QCT Bone Mineral Density Analysis Software -
B052QCTPROM0SS0 - QCT PRO 3D Volumetric Spine Software2018-07-06 Convenience Kit consisting of - QCT Bone Mineral Density Analysis Software - Accessories