Component TE-G With Tylan by is a Animal medication manufactured, distributed, or labeled by Elanco US Inc.. Drug facts, warnings, and ingredients follow.
Each cartridge belt holds 20 doses of Component TE-G with Tylan (trenbolone and estradiol and tylosin implant) Implants. Each dose of 3 pellets consists of 2 pellets containing a total of 40 mg of trenbolone acetate and 8 mg estradiol plus 1 pellet containing 29 mg tylosin tartrate as a local antibacterial. Component TE-G (trenbolone and estradiol implant) Implants are recommended for use in pasture cattle (slaughter, stocker, and feeder steers and heifers) for INCREASED RATE OF WEIGHT GAIN.
Study the instructions which should be followed carefully at all times, avoiding short cuts. Skin infection can be avoided by properly preparing implant site and implanter. During fly season use fly repellent on implant site. One designated team member should always do the implanting. Cleanliness of hands and instruments is important at all times.
Not to be used in animals intended for subsequent breeding, or in dairy animals. Implant one dose — 3 pellets (entire contents of one cartridge cell) — in the ear subcutaneously. Any other site of implantation is in violation of Federal Law. DO NOT attempt to salvage implantation site for animal feed or human food.
A withdrawal period has not been established for this product in pre-ruminating calves. Do not use in calves to be processed for veal.
RESTRICTED DRUG (CALIFORNIA) — USE ONLY AS DIRECTED — FOR USE IN ANIMALS ONLY — NOT FOR HUMAN USE — KEEP OUT OF REACH OF CHILDREN
IMPLANTING INSTRUCTIONS:
Speed of implantation as well as safety of handlers is best achieved by restraining animal in a squeeze chute using head restraint. When implanting horned cattle, better control is obtained with additional use of nose tongs.
Scrub the back side of the ear (implant site) with a piece of clean absorbent cotton which has been soaked with topical germicidal solution. Follow manufacturer's directions on germicide for correct strength and preparation of solution. Avoid getting disinfectant in animal's eyes.
The full contents of one cartridge cell should be implanted beneath the skin on the back side of the middle one-third of the ear as illustrated in the drawing. The implant must not be closer to the head than the edge of the auricular cartilage ring farthest from the head. The location for insertion of the needle is a point toward the tip of the ear at least a needle length away from the intended deposition site. Avoid injuring the large arteries, veins and cartilage of the ear.
With one hand firmly grasp the ear. With the other hand insert needle point through the skin and ease forward on a lateral plane until the entire length of the needle is under the skin.
After inserting the needle fully in the correct position, squeeze the trigger fully as the needle is withdrawn from the ear. This properly deposits the implant in the needle track. This procedure should prevent breakage or crushing of pellets if otherwise forced into contact with tough fibrous-tissue underlying the skin. The length and total contact area of the single dose are designed to permit absorption of the hormones after implantation to stimulate good weight gain. Broken or crushed pellets may interfere with rates of gain.
Store in a refrigerator 2° to 8°C (36° to 46°F) and protect from sunlight.
Use before the expiration date printed on foil pouch. Discard open foil pouches.
ANADA 200-221, Approved by FDA
Manufactured by a non-sterilizing process.
Component TE-G with Tylan is covered by U.S. Patent No. 5,874,098
Component, Tylan, Elanco and the diagonal bar logo are trademarks of Elanco or its affiliates.
Distributed by Elanco US Inc, Greenfield, IN 46140, USA
Tylosin: Product of the United Kingdom
To report adverse events, access medical information, or to obtain additional product information, call 1-800-428-4441
COMPONENT TE-G WITH TYLAN
trenbolone acetate, estradiol, tylosin tartrate implant |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Labeler - Elanco US Inc. (966985624) |