A component of a remote afterloading brachytherapy system consisting of a shielded vault, and associated source retraction and extrusion mechanisms, alarms, and related mechanical, electronic and software controls, used to shield the brachytherapy sources i...
A tube or hose-like catheter with connectors at both ends used to interface the brachytherapy applicator to the remote afterloading system. The transfer tube, when attached to the applicator and the afterloading system, provides a continuous closed passage ...
A manual brachytherapy applicator specifically designed to be used in radiation therapy treatments of the prostate. It is an individual or modular device designed to facilitate manual placement, e.g., puncture, endoscopically guided or diagnostic imaging sy...
A manual brachytherapy applicator specifically designed to be used in cervical and/or intrauterine radiation therapy treatments. It is an individual or modular device designed to facilitate manual placement, e.g., puncture, endoscopically guided placement o...
A manual brachytherapy applicator specifically designed to be used in vaginal or transvaginal radiation therapy treatments. It is an individual or modular device designed to facilitate manual placement, e.g., puncture, topical placement, endoscopically guid...
A manual brachytherapy applicator specifically designed to be used in radiation therapy treatments of the bile duct. It is an individual device designed to facilitate manual placement, e.g., puncture, endoscopically guided or diagnostic imaging system guide...
A manual brachytherapy applicator specifically designed to be used in radiation therapy treatments of the bladder. It is an individual device designed to facilitate manual placement, e.g., endoscopically guided or diagnostic imaging system guided placement,...
A sterile flexible tube intended to deliver/remove radiation therapy sources into a coronary artery, typically into the lumen of an implanted stent, as part of a manual-afterloading brachytherapy system. It is introduced into the patient and subsequently co...
A device in the form of a template that is shielded on one side and containing grooved positions for manual brachytherapy sources on the other used for the temporary topical application of brachytherapy sources to the surface of the eye.
A manual brachytherapy applicator specifically designed to be used in radiation therapy treatments of the oesophagus. It is an individual or modular device designed to facilitate manual placement, e.g., puncture, endoscopically guided or diagnostic imaging ...
A general-purpose remote-afterloading brachytherapy applicator intended to be used to facilitate the delivery of radiation therapy treatments in a range of anatomical regions (e.g., liver, kidneys, lungs, gastrointestinal tract). It is designed for temporar...
A remote afterloading brachytherapy applicator specifically designed for use in cervical or intrauterine radiation therapy treatments. It is designed for temporary implantation within the body and serve as a guide for computer-controlled placement and remov...
A general-purpose brachytherapy applicator designed to facilitate delivery of radiation therapy treatments that are not specific to a particular anatomical region. It is an individual or modular device designed to facilitate manual placement, e.g., puncture...
A sterile, sharp bevel-edged, hollow tubular metal instrument that is used to inject radionuclide into a body cavity or tissue as a source of nuclear radiation for cancer therapy (brachytherapy). The device may be pre-sterilized and preloaded, and may have ...
A remote afterloading brachytherapy applicator specifically designed for use in vaginal or transvaginal radiation therapy treatments. It is designed for temporary implantation within the body and serves as a guide for computer-controlled placement and remov...
A remote afterloading brachytherapy applicator specifically designed for use in radiation therapy treatments of the prostate. It is designed for temporary implantation within the prostate and serve as a guide for computer-controlled placement and removal of...
An assembly of therapeutic, independent devices, manually brought together and intended to deliver a palliative or therapeutic radiation dose to an anatomical region from radionuclide sources. Medical personnel manually place multiple radioactive sources in...
A device that is a naturally-occurring, accelerator- or reactor-produced radioactive isotope in a form that is intended for temporary placement in the body and removal after a specified treatment time. It is used in brachytherapy applications that require d...
A sharp bevel-edged, hollow tubular metal instrument that is used to inject radionuclide into a body cavity or tissue as a source of nuclear radiation for cancer therapy (brachytherapy). The device may be pre-sterilized and preloaded, and may have a tip enh...
A remote afterloading brachytherapy applicator specifically designed for use in radiation therapy treatments of the rectum and/or anus. It is designed for temporary implantation within the rectum and/or anus and serve as a guide for computer-controlled plac...
A remote afterloading brachytherapy applicator specifically designed for use in bronchial radiation therapy treatments. It is designed for temporary placement within the body and serve as a guide for computer-controlled placement and removal of single or mu...
A remote afterloading brachytherapy applicator specifically designed for use in radiation therapy treatments of the oesophagus. It is designed for temporary implantation within the oesophageal region and serve as a guide for computer-controlled placement an...
A remote afterloading brachytherapy applicator specifically designed for use in radiation therapy treatments of the tongue or oral cavity. It is typically designed for temporary implantation within the tongue and/or the tissue surrounding the tongue and ser...
A sterile, remote-afterloading brachytherapy applicator specifically designed for use in radiation therapy treatments of the breast. It is typically designed for temporary implantation within the breast and serves as a guide for computer-controlled placemen...
A remote afterloading brachytherapy applicator specifically designed for use in radiation therapy treatments of the nasopharynx region. It is designed for temporary implantation within the body and serve as a guide for computer-controlled placement and remo...
A collection of sterile devices intended to dispense/collect hydraulic fluid used to deliver the radiation source train of a manual-afterloading brachytherapy system source transfer device to/from the delivery catheter/applicator. It consists of disposable ...
A device that is a naturally-occurring, accelerator or reactor produced-radioactive isotope used as a source of radiation in high or low dose rate remote afterloading brachytherapy systems designed to deliver curative or palliative radiotherapy treatments. ...
A device specifically designed to be used in radiation therapy treatments of the brain. It has individual or modular device configurations designed to facilitate manual placement, e.g., puncture, endoscopically guided placement or diagnostic imaging guided ...
A collection of non-sterile devices intended to be used with a manual-afterloading brachytherapy system to provide various additional functions including: fluid sampling for subsequent assessment of transferable radioactive contamination, dry/store componen...
A non-sterile radiation-shielding plastic box intended to store a manual-afterloading brachytherapy system. It is typically temporarily used as a safety container to prevent radiation leakage in the event of procedural difficulties.